  • Code: SC317
  • Description: Drum Charge Error: M
    Drum charge output voltage (Vpp) exceeded 2.8 kV.
  • Causes: • Check the connections of the charge unit of the PCU where the problem occurred. • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
  • Code: SC318
  • Description: Drum Charge Error: C
    Drum charge output voltage (Vpp) exceeded 2.8 kV.
  • Causes: • Check the connections of the charge unit of the PCU where the problem occurred. • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
  • Code: SC319
  • Description: Drum Charge Error: Y
    Drum charge output voltage (Vpp) exceeded 2.8 kV.
  • Causes: • Check the connections of the charge unit of the PCU where the problem occurred. • Replace the charge unit of the PCU (CBG power pack for the K PCU, charge roller unit for YMC PCUs)
  • Code: SC320
  • Description: Development power pack error: K
    This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y.
  • Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
  • Code: SC321
  • Description: Development power pack error: M
    This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y.
  • Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
  • Code: SC322
  • Description: Development power pack error: C
    This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y.
  • Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
  • Code: SC323
  • Description: Development power pack error: Y
    This SC is issued if the VBCU detects a short in the development DC charge for K, M, C, Y.
  • Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
  • Code: SC324
  • Description: Development motor error: K
    The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
  • Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective