Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC7501 — Trang 10/44

Code: SC325

Description: Development motor error: M
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective

Code: SC326

Description: Development motor error: C
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective

Code: SC327

Description: Development motor error: Y
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the K, M, C, or Y, development motor.
Causes: • Development motor shaft locked, blocked by obstruction • Development motor defective • DRB defective

Code: SC336

Description: Developer set error: K
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y

Code: SC337

Description: Developer set error: M
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y

Code: SC338

Description: Developer set error: C
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y

Code: SC339

Description: Developer set error: Y
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: 1. Open the front door. 2. Pull out the film seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the correct SP for the affected color: • SP3801 003 to initialize the TD sensor for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for Y

Code: SC348

Description: Toner supply motor error
2 sec. after the motor START signal is output, a LOCK signal cannot be detected.
Causes: • Motor harness disconnected, loose, or defective • Toner pump overload • Sub hopper overload • Toner hopper motor defective
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie