Description: Toner supply motor error (K). Detected a lock signal which indicates overcurrent in the toner supply bottle motor. Details: The lock signal is generated when the toner supply bottle motor current exceeds 500 mA. When a toner supply bottle motor is on, it is checked every 100 milliseconds for lock signals. The following steps are executed every second. • If the lock signal was detected 9 times in 10 samplings, the lock counter increases by one. When the lock counter value is 23 or larger, the SC is issued. • If the lock signal was detected 8 times or less in 10 samplings, the lock counter is cleared. • If the samplings end before reaching the tenth time (due to bottle replacement etc.), the lock counter value is kept as is. Sampling starts again the next time the motor runs. • The lock counter is cleared when the machine is turned off (also when the machine enters sleep mode, in which the plotter is turned off) or when an SC is issued.
Causes: • Toner bottle not set correctly or the torque is large. • Toner bottle broken or defective • Motor defective
Remedy: • Toner bottle not set correctly, toner bottle broken, or large torque: After the machine stops, ask the user to remove the toner bottle, shake it and set it again. Then cycle the machine off/on to return from SC status. • Toner bottle broken or defective: Ask the user to remove the toner bottle and set a normal bottle. Then cycle the machine off/on to return from SC status. • Motor defective: Turn off the machine and replace the motor. Then cycle the machine off/on to return from SC status.
Code: SC332-02
Description: Toner supply motor error (C). Detected a lock signal which indicates overcurrent in the toner supply bottle motor. Details: The lock signal is generated when the toner supply bottle motor current exceeds 500 mA. When a toner supply bottle motor is on, it is checked every 100 milliseconds for lock signals. The following steps are executed every second. • If the lock signal was detected 9 times in 10 samplings, the lock counter increases by one. When the lock counter value is 23 or larger, the SC is issued. • If the lock signal was detected 8 times or less in 10 samplings, the lock counter is cleared. • If the samplings end before reaching the tenth time (due to bottle replacement etc.), the lock counter value is kept as is. Sampling starts again the next time the motor runs. • The lock counter is cleared when the machine is turned off (also when the machine enters sleep mode, in which the plotter is turned off) or when an SC is issued.
Causes: • Toner bottle not set correctly or the torque is large. • Toner bottle broken or defective • Motor defective
Remedy: • Toner bottle not set correctly, toner bottle broken, or large torque: After the machine stops, ask the user to remove the toner bottle, shake it and set it again. Then cycle the machine off/on to return from SC status. • Toner bottle broken or defective: Ask the user to remove the toner bottle and set a normal bottle. Then cycle the machine off/on to return from SC status. • Motor defective: Turn off the machine and replace the motor. Then cycle the machine off/on to return from SC status.
Code: SC332-03
Description: Toner supply motor error (M). Detected a lock signal which indicates overcurrent in the toner supply bottle motor. Details: The lock signal is generated when the toner supply bottle motor current exceeds 500 mA. When a toner supply bottle motor is on, it is checked every 100 milliseconds for lock signals. The following steps are executed every second. • If the lock signal was detected 9 times in 10 samplings, the lock counter increases by one. When the lock counter value is 23 or larger, the SC is issued. • If the lock signal was detected 8 times or less in 10 samplings, the lock counter is cleared. • If the samplings end before reaching the tenth time (due to bottle replacement etc.), the lock counter value is kept as is. Sampling starts again the next time the motor runs. • The lock counter is cleared when the machine is turned off (also when the machine enters sleep mode, in which the plotter is turned off) or when an SC is issued.
Causes: • Toner bottle not set correctly or the torque is large. • Toner bottle broken or defective • Motor defective
Remedy: • Toner bottle not set correctly, toner bottle broken, or large torque: After the machine stops, ask the user to remove the toner bottle, shake it and set it again. Then cycle the machine off/on to return from SC status. • Toner bottle broken or defective: Ask the user to remove the toner bottle and set a normal bottle. Then cycle the machine off/on to return from SC status. • Motor defective: Turn off the machine and replace the motor. Then cycle the machine off/on to return from SC status.
Code: SC332-04
Description: Toner supply motor error (Y). Detected a lock signal which indicates overcurrent in the toner supply bottle motor. Details: The lock signal is generated when the toner supply bottle motor current exceeds 500 mA. When a toner supply bottle motor is on, it is checked every 100 milliseconds for lock signals. The following steps are executed every second. • If the lock signal was detected 9 times in 10 samplings, the lock counter increases by one. When the lock counter value is 23 or larger, the SC is issued. • If the lock signal was detected 8 times or less in 10 samplings, the lock counter is cleared. • If the samplings end before reaching the tenth time (due to bottle replacement etc.), the lock counter value is kept as is. Sampling starts again the next time the motor runs. • The lock counter is cleared when the machine is turned off (also when the machine enters sleep mode, in which the plotter is turned off) or when an SC is issued.
Causes: • Toner bottle not set correctly or the torque is large. • Toner bottle broken or defective • Motor defective
Remedy: • Toner bottle not set correctly, toner bottle broken, or large torque: After the machine stops, ask the user to remove the toner bottle, shake it and set it again. Then cycle the machine off/on to return from SC status. • Toner bottle broken or defective: Ask the user to remove the toner bottle and set a normal bottle. Then cycle the machine off/on to return from SC status. • Motor defective: Turn off the machine and replace the motor. Then cycle the machine off/on to return from SC status.
Code: SC336-01
Description: Developer Set Error (K). When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output (Vt) is less than 0.7V. Details: When executing TD sensor initialization (SP3-030), the machine checks the development unit for the presence of developer. If the error condition is detected at this point, the machine determines that there is no developer and issues the SC.
Causes: • There is an extremely low amount of developer.
Remedy: • Check the developer.
Code: SC336-02
Description: Developer Set Error (C). When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output (Vt) is less than 0.7V. Details: When executing TD sensor initialization (SP3-030), the machine checks the development unit for the presence of developer. If the error condition is detected at this point, the machine determines that there is no developer and issues the SC.
Causes: • There is an extremely low amount of developer.
Remedy: • Check the developer.
Code: SC336-03
Description: Developer Set Error (M). When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output (Vt) is less than 0.7V. Details: When executing TD sensor initialization (SP3-030), the machine checks the development unit for the presence of developer. If the error condition is detected at this point, the machine determines that there is no developer and issues the SC.
Causes: • There is an extremely low amount of developer.
Remedy: • Check the developer.
Code: SC336-04
Description: Developer Set Error (Y). When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output (Vt) is less than 0.7V. Details: When executing TD sensor initialization (SP3-030), the machine checks the development unit for the presence of developer. If the error condition is detected at this point, the machine determines that there is no developer and issues the SC.
Causes: • There is an extremely low amount of developer.