Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SPC420DN — Trang 3/15

Code: 233

Description: FGATE: Off error [Y]
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [K] ends. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.

Code: 234

Description: FGATE: On error [M]
The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [M] started.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.

Code: 235

Description: FGATE: Off error [M]
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [M] ends. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.

Code: 236

Description: FGATE: On error [C]
The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [C] started.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.

Code: 237

Description: FGATE: Off error [C]
The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [C] ends. • The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.

Code: 240

Description: LDB error [K]
The EGB detects LDB error an the few times consecutively when LDB unit turns on after LDB initialization.
Causes: Defective LDB
Remedy: 1. Replace the LDB.

Code: 241

Description: LDB error [Y]
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: Defective LDB
Remedy: 1. Replace the LDB.

Code: 242

Description: LDB error [M]
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: Defective LDB
Remedy: 1. Replace the LDB.