Code: 365

Description: TD sensor Output minimum error [M]
Vt is less than the minimum value (0.5) for three times consecutively.
Causes: Defective connector connection. Decreasing toner density
Remedy: 1. Replace the PCU.

Code: 366

Description: TD sensor: Output minimum error [C]
Vt is less than the minimum value (0.5) for three times consecutively.
Causes: Defective connector connection. Decreasing toner density
Remedy: 1. Replace the PCU.

Code: 367

Description: TD sensor: Output minimum error [Y]
Vt is less than the minimum value (0.5) for three times consecutively.
Causes: Defective connector connection. Decreasing toner density
Remedy: 1. Replace the PCU.

Code: 368

Description: TD sensor: Initial control voltage error [K]
Vt is less than 1 V even though the control power voltage is adjusted to the maximum. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: Defective connector connection. Defective TD sensor. The toner density in the developer is different.
Remedy: 1. Replace the PCU.

Code: 369

Description: TD sensor: Initial control voltage error [M]
Vt is less than 1 V even though the control power voltage is adjusted to the maximum. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: Defective connector connection. Defective TD sensor. The toner density in the developer is different.
Remedy: 1. Replace the PCU.

Code: 370

Description: TD sensor: Initial control voltage error [C]
Vt is less than 1 V even though the control power voltage is adjusted to the maximum. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: Defective connector connection. Defective TD sensor. The toner density in the developer is different.
Remedy: 1. Replace the PCU.

Code: 371

Description: TD sensor: Initial control voltage error [Y]
Vt is less than 1 V even though the control power voltage is adjusted to the maximum. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: Defective connector connection. Defective TD sensor. The toner density in the developer is different.
Remedy: 1. Replace the PCU.

Code: 372

Description: TD sensor: Initial adjustment error [K]
Vt is not (A +-0.2) when initial setting for TD sensor is executed. A = SP3011-001 for [K]
Causes: Defective connector connection. Defective TD sensor. The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.