Code: 243

Description: LDB error [C]
The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Defective LDB
Remedy: 1. Replace the LDB.

Code: 270

Description: LDU shutter error
Sensor output does not change even if 1 second passes after the LDU shutter motor is on.
Causes: Sensor defective or LDU shutter motor defective
Remedy: 1. Replace the LDU shutter sensor or shutter motor.

Code: 300

Description: High voltage power board: Charge voltage output error [K]
The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.

Code: 301

Description: High voltage power board: Charge voltage output error [M]
The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.

Code: 302

Description: High voltage power board: Charge voltage output error [C]
The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for cyan. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.

Code: 303

Description: High voltage power board: Charge voltage output error [Y]
The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller Defective connectors Disconnected harness Defective high voltage power 1
Remedy: 1. Check the connectors. 2. Replace the PCU for yellow. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.

Code: 304

Description: Charge AC bias error [K]
The charge current less than 200 mkA is detected.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate.

Code: 305

Description: Charge AC bias error [M]
The charge current less than 200 mkA is detected.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.