Description: FGATE ON error: Bk The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE OFF error: Bk • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE ON error: Y The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE OFF error: Y • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE ON error: M The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [M].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE OFF error: M • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE ON error: C The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [C].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Description: FGATE OFF error: C • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and EGB. • Defective EGB
Remedy: 1. Check the connection between the controller board and the BCU. 2. Replace the BCU. 3. Replace the controller board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.