Description: LD error: Bk The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BCU.
Code: 241
Description: LD error: Y The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BCU.
Code: 242
Description: LD error: M The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BCU.
Code: 243
Description: LD error: C The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BCU.
Code: 285
Description: Line position adjustment (MUSIC) error Line position adjustment fails four consecutive times.
Causes: • Pattern sampling error ( insufficient image density ) • Defective ID sensors for the line position adjustment • Defective image transfer belt unit • Defective PCU(s) • Defective laser optics housing unit
Remedy: 1. Check and reinstall the image transfer belt unit and PCUs. 2. Check if each toner bottle has enough toner. 3. Replace the ID sensor. 4. Replace the image transfer belt unit. 5. Replace the PCU(s). 6. Replace the laser optics housing unit.
Code: 300
Description: AC charge output error [K] The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.
Code: 301
Description: AC charge output error [M] The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.
Code: 302
Description: AC charge output error [C] The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.