Code: 367

Description: TD sensor (Vt low) error 2: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector disconnected, loose, defective • TD sensor defective
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCU for damage. 2. Check the drawer connector. 3. Replace the defective PCU.

Code: 372

Description: TD sensor adjustment error: K
During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.

Code: 373

Description: TD sensor adjustment error: M
During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.

Code: 374

Description: TD sensor adjustment error: C
During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.

Code: 375

Description: TD sensor adjustment error: Y
During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCU. 2. Replace the defective PCU.

Code: 380

Description: Drum gear position sensor error: K
The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.

Code: 381

Description: Drum gear position sensor error: M
The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.

Code: 382

Description: Drum gear position sensor error: C
The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCU.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie