Description: Zero cross error
When the main switch is turned on, the machine checks how many zero-cross signals are generated within 500 ms. This SC code is issued if the number of zero-cross signals detected is either more than 66 or less than 45 for 10 readings. Note: Zero cross signals, generated from an ac power supply, are used to generate a trigger pulses to control the applied power accurately.
Causes: • Electrical noise on the power supply line • Fusing relay damaged: replace the PSU.
Description: Heating roller thermistor 2 error 2: Failed to reach warmup temperature
After the main switch is turned on or the cover is closed, the heating roller temperature does not reach the ready temperature within 2 sec. after the heater switches on. -or- If the roller was below 45°C, the heating roller did not reach the ready temperature 2 sec. after reaching 45°C. Note: Thermistor 2 stops monitoring the temperature once Thermistor 1 detects warmup temperature.
Description: Pressure roller thermistor error 2
After the main switch is turned on or the cover is closed, the heating roller temperature does not reach the ready temperature within 2 sec. after the heater switches on. -or- If the roller was below 45°C, the heating roller did not reach the ready temperature 2 sec. after reaching 45°C. Note: Thermistor 2 stops monitoring the temperature once Thermistor 1 detects ready temperature.