Các lỗi thường gặp

Code :
  • Code: 623
  • Description: Communication timeout error between BICU and paper tray unit
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the paper tray unit.
  • Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray main board connection defective or loose • Paper tray main board defective • BICU board defective
  • Code: 624
  • Description: Communication break error between BICU and paper tray unit
    The BICU cannot communicate with the paper tray unit due to receiving a break signal.
  • Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray unit connection defective • Optional paper tray unit interface board defective • BICU board defective
  • Code: 626
  • Description: Communication timeout error between BICU and LCT
    The BICU cannot receive a response within 100 ms after 3 attempts after attempting to communicate with the LCT.
  • Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
  • Code: 627
  • Description: Communication break error between BICU and LCT
    The BICU cannot communicate with the LCT unit due to receiving a break signal.
  • Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
  • Code: 670
  • Description: Engine startup error
    The BICU failed to respond with the prescribed time when the machine was turned on.
  • Causes: • Connections between BICU and controller board are loose, disconnected, or damaged • Replace the BICU • Replace the controller board
  • Code: 672
  • Description: Controller startup error
    • After power on, the line between the controller and the operation panel did not open for normal operation. • After normal startup, communication with the controller stopped.
  • Causes: • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective
  • Code: 692
  • Description: GAVD block 12C bus error
    The I2C bus of the BICU is defective
  • Causes: • Replace BICU
  • Code: 722
  • Description: Finisher jogger motor error
    The finisher jogger HP sensor did not return to the home position, or move out of the home position, within 1.25 sec. Staple mode cannot be used.
  • Causes: • Jogger motor connector or harness loose, broken, defective • Jogger motor defective • Jogger HP sensor connector or harness loose, broken, defective • Jogger HP sensor defective