Description: Fusing Temperature: Error 2 (Hardware Detection) The fusing thermistor that monitors the temperature of the hot roller detected a fusing temperature of 235oC (455oF), due to a Triac short which interfered with fusing temperature control.
Description: Fusing Temperature: Error 3 After the hot roller reached the ready temperature, the fusing lamp stayed on at full power for 50 sec. while the hot roller was not rotating.
Causes: • Hot roller thermistor not positioned correctly • Fusing lamp harness loose, disconnected, defective • MCU defective
Remedy:
Code: 546
Description: Fusing Temperature: Error 4 The machine detected that the fusing temperature was fluctuating out of range for more than 60 sec. (7 readings detected temperature fluctuating more than ±20C)
Description: Zero-Cross Signal Errors This error occurs if the machine fails to detect 50/60 Hz on the power supply line. Note: The zero-cross signal from the ac power supply generates a trigger pulse to control the power supply of power. (It automatically detects 50/60 Hz.)
Causes: • Check that the frequency of the power supply to the machine is correct • PSU defective • MCU defective
Remedy:
Code: 551
Description: Pressure roller center thermistor error 1. During the hot roller temperature control sequence, or while the hot roller and pressure roller were rotating, the pressure roller center thermistor measured a value higher than 3.3V 10 consecutive times at 600 ms intervals.
Causes: • Pressure roller center thermistor not positioned properly • Pressure roller center thermistor connector loose, broken, defective • Pressure roller center thermistor defective • MCU defective
Remedy:
Code: 553
Description: Pressure roller center thermistor error 2 During the hot roller temperature control sequence, the pressure roller center thermistor measures a value lower than 0.2V.
Causes: • Pressure roller center thermistor not positioned properly • Pressure roller center thermistor connector loose, broken, defective • Pressure roller center thermistor defective • MCU defective
Remedy:
Code: 557
Description: Applied zero-cross waveform error The applied power ac frequency was detected less than 66 Hz more than 10 times.
Causes: • Noise on the ac power supply line
Remedy:
Code: 559
Description: Fusing paper jam errors Three consecutive paper jam errors occurred in the fusing unit. Note: This SC code is not issued unless SP1159 is switched on.
Causes: • Paper jam in fusing unit • Pick-off pawl defective • Paper scraps in fusing unit • Exit sensor defective