Các lỗi thường gặp

Code :
  • Code: 632 U09
  • Description: Booklet Tamper R Home SNR ON fail
    •Tamper R Home SNR does not turn ON within 1000 msec of Mot ON when the Booklet Tamper R returns to the home position.
  • Code: 633 U09
  • Description: Booklet Tamper R Home SNR OFF fail
    •Tamper R Home SNR does not turn OFF even when the Booklet Tamper R MOT outputs 75 pulses.
  • Code: 634 U09
  • Description: Booklet Knife Folding SNR fail
    •Booklet Folding SNR does not turn ON within 520 msec of Flapper SOL ON when the Booklet Knife is engaged in a folding operation.
  • Code: 635 U09
  • Description: Booklet Drawer broken fail
    •Booklet Drawer SNR OPEN detected when Finisher Front Door interlock is closed.
  • Code: 636 U09
  • Description: Booklet Knife Home SNR ON fail
    •Home SNR does not turn ON within 900 msec of Flapper SOL ON when the Booklet Knife returns to the home position.
    •Knife Home SNR is OFF while the Knife is engaged in a folding operation for a booklet.
  • Code: 637 U09
  • Description: Booklet Knife Home SNR OFF fail
    •Home SNR does not turn OFF within 150 msec of Flapper SOL ON when the Booklet Knife is moving away from the position.
  • Code: 638 U09
  • Description: Booklet Stapler fail
    •Stapler Ready signal does not change to Not Ready within the preset interval after Booklet Staple Start signal ON. (= Stapler does not operate)
    •Error signal ON or Ready signal OFF from Stapler detected during Stapler power ON check processing in power ON or interlock close.
    •Ready signal remains at Not Ready status within the specified interval after detection of Stapler NG, or Error signal turns ON.
    •Error signal turns ON immediately before a Staple command is issued.
  • Code: 660 S18
  • Description: Connected unit Transport Motor lock
    •Transport Motor lock occurred in the connected unit.