Description: Dec. 1Home SNR OFF fail
•Dec. 1Home SNR does not turn OFF within 300 msec after operation startup.
Code: 662 S19
Description: Dec. 1Home SNR ON fail
•Dec. 2Home SNR does not turn ON within 1000 msec after detection of Dec. 1Home SNR OFF.
•Dec. 2Home SNR does not turn ON after operation termination following Dec. 1Home SNR ON.
Code: 663 S20
Description: Punch Home SNR ON fail
•Punch Home SNR does not turn ON within 1000 msec after operation startup.
Code: 664 S20
Description: Punch Home SNR OFF fail
•Punch Home SNR does not turn OFF within 100 msec after operation startup.
Code: 665 S20
Description: Puncher Move Home SNR OFF fail
•Puncher Move Home SNR does not turn OFF within 1000 (100*) msec after operation startup.
•Puncher Move Home SNR does not turn OFF after operation termination following Puncher Move Home SNR OFF.
Code: 666 S20
Description: Puncher Move Home SNR ON fail
•Puncher Move Home SNR does not turn ON within 400 (300*500**) msec after operation startup.
•Puncher Move Home SNR does not turn ON after operation termination following Puncher Move Home SNR ON.
Code: 667 S20
Description: Side Regi. Home SNR OFF fail
•Side Regi. Home SNR does not turn OFF within 1000 msec after operation startup.
•Side Regi. Home SNR does not turn OFF after operation termination following Side Regi. Home SNR OFF.
Code: 668 S20
Description: Side Regi. Home SNR ON fail
•Side Regi. Home SNR does not turn ON within 1000 or 300 msec after operation startup.
•Side Regi. Home SNR does not turn ON after operation termination following Side Regi. Home SNR ON.