Description: Finisher communication error 1 (HC Finisher & HC Auto Stacker)
HC Finisher
•Communication error occurred between the HC Control PCB and Finisher.
•Problem occurred in the command sequence. (command sequence error)
HC Auto Stacker
•Break signal received and initial communication cannot be made when the power is turned ON.
•Command was not received in correct sequence timing.
•No reply from HC Auto Stacker within 200ms after its power is turned ON.
•The firmware version number is not replied back within 200 ms.
•Ready reply is not replied back from HC Auto Stacker within 400ms after power is turned ON.
•Energy saving mode is not replied back from HC Auto Stacker within 500ms from power ON.
•No reply from HC Auto Stacker against the command given.
•Command sequence error.
•Large amount of data is received at one time (buffer full in data receiving).
•Large amount of data is sent at one time (buffer full in data sending).
Description: Finisher communication error 2 (HC Finisher & HC Auto Stacker)
•Communication error occurred between the HC Control PCB and Finisher or HC Auto Stacker.
•Undefined command was received. (undefined command reception)
Description: Finisher communication error 3 (HC Finisher & HC Auto Stacker)
HC Finisher
•No reply from HC Finisher within 40 ms for two consecutive tries.
HC Auto Stacker
•No reply from HC Finisher within 100 ms for two consecutive tries.
Description: Finisher communication error 4 (HC Finisher & HC Auto Stacker)
•Communication error occurred between the HC Control PCB and Finisher or HC Auto Stacker.
•No ACK was received within the specified interval after command transmission. (ACK reception timeout)
Description: Finisher communication error 5 (HC Finisher & HC Auto Stacker)
HC Finisher
•The sequence bit of the received ACK does not conform to the standard. (ACK sequence bit error)
HC Auto Stacker
•After confirming the HC Auto Stacker power ON, the first data frame identification received is not odd number.
Description: Finisher communication error 6
•Communication error occurred between the PRH and Finisher.
•The sequence bit of command received by the PRH does not conform to the standard. (received command sequence bit error)
Description: Finisher communication error 7
•Communication error occurred between the PRH and Finisher.
•The checksum of the command received by the PRH does not conform to the standard. (command packet checksum error)
Description: Finisher communication error 8 (HC Finisher & HC Auto Stacker)
HC Finisher
•The length of the command received by the HC Control PCB does not conform to the standard. (command packet length error)
HC Auto Stacker
•The length of the data frame received by the HC Control PCB does not conform to the standard.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.