Description: M ain-M otorLock (CALL SERVICE E01)
Ifno encodersignalis delivered even aftera certain tim e period has elapsed since the m ain m otorbegan running · Ifan overcurrentflows continuouslyfor0.8 sec when the m ain m otor starts running
Description: Elevator-M otorLock (CALL SERVIC E E02)
Ifthe upper-lim itsensordoes notcom e on even afterseven seconds has elapsed since the elevatorm otorbegan running in the ascending direction
Ifthe lower-lim itsensordoes notcom e on even afterseven seconds has elapsed since the elevatorm otorbegan running in the descending direction · Ifan overcurrentflows continuouslyfor0.8 sec when the m ain m otor starts running
Description: Stacker-M otorLock (CALL SERVIC E E03)
Ifthe statuses ofthe stackersensorand stackerhom e sensordo not change form ore than one second following the startofoperation of the stackerm otor
Description: C onnection I/F com m unication error(CALL SERVIC E E04)
Ifthe m achine is operated through connection to anotherm achine and an erroroccurs in com m unication with the M asterm achine or Slave machine
Description: Postprocessing-m achine I/F com m unication error (CALL SERVIC E E05)
If a postprocessing m achine is used and an erroroccurs in com m unication with the postprocessing m achine
Description: Stacker-area connection error(CALL SERVIC E E06)
Ifthe poweris turned on withoutthe stackerarea connected to the connectorofthe m achine m ain unit