Code :
  • Code: 0002
  • Description: Disorder of communication with Sub CPU
  • Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board.
  • Code: 0004
  • Description: SRAM error
  • Causes: SRAM has broken.
  • Code: 0005
  • Description: An error occurs during downloading a program for sub CPU.
  • Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal.
  • Code: 0006
  • Description: An error occurs when start connecting to sub CPU.
  • Causes: A noise on a signal during sending a command. Sub CPU was reset to default. Get into communicate when Sub CPU was reset to default.
  • Code: 0007
  • Description: An error occurs during sending a command.
  • Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal during sending a command. Sub CPU was reset during sending a command.
  • Code: 0008
  • Description: There is a problem with synchronizing serial communication to Sub CPU.
  • Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Heater Board and Servo Board. There is a bad connection between Main Board and Heater Board. A noise on a signal.
  • Code: 0101
  • Description: Limit Position Initialize has not been done.
  • Causes: Limit Position Initialize has not been done.
  • Code: 0102
  • Description: Even though the machine carries out the regular movement, the output of Limit Sensor does not reach the expected value.
  • Causes: Limit Sensor does not work correctly or is broken.