Display: LSU error: #04-001. Please turn off then on
Description: After LD on, the Laser beam detect signal is not occurred or irregular.
Remedy: 1. Check the Beam Detecht signal. If there is a BD signal, replace the Main board. If or not, check the LD contol signal. 2. Check the LD Power is normal. 3. If it is normal, check the light receving part.
Display: LSU error: #04-004. Please turn off then on
Description: After Yellow LD on, the Laser beam detect signal is not occurred or irregular.
Remedy: 1. Check the Beam Detecht signal. If there is a BD signal, replace the Main board. If or not, check the LD contol signal. 2. Check the LD Power is normal. 3. If it is normal, check the light receving part.
Display: LSU error: #04-007. Please turn off then on
Description: After Magenta LD on, the Laser beam detect signal is not occurred or irregular.
Remedy: 1. Check the Beam Detecht signal. If there is a BD signal, replace the Main board. If or not, check the LD contol signal. 2. Check the LD Power is normal. 3. If it is normal, check the light receving part.
Display: LSU error: #04-010. Please turn off then on
Description: After Cyan LD on, the Laser beam detect signal is not occurred or irregular.
Remedy: 1. Check the Beam Detecht signal. If there is a BD signal, replace the Main board. If or not, check the LD contol signal. 2. Check the LD Power is normal. 3. If it is normal, check the light receving part.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.