Remedy: 1. Open and close the door. If the message is not disappeared, check the below steps. 2. Check that the door switch is pushed. 3. Check that the Ui message is chaged by door switch action. 4. Check the door switch signal on EDC mode.
Display: Tray2 door is open. Close it or Tray2(HCF) door is open. Close it
Description: Tray2 or Tray2 HCF door is open.
Remedy: 1. Open and close the door. If the message is not disappeared, check the below steps. 2. Check that the door switch is pushed. 3. Check that the Ui message is chaged by door switch action. 4. Check the door switch signal on EDC mode.
Remedy: 1. Open and close the door. If the message is not disappeared, check the below steps. 2. Check that the door switch is pushed. 3. Check that the Ui message is chaged by door switch action. 4. Check the door switch signal on EDC mode.
Display: System error: #02-000. Please turn off then on
Description: 1. At warm up, the temperature is less than reference temperature for 20 sec. 2. Abnormal ADC has occurred. 3. ZeroCross Signal detect error has occurred.
Remedy: 1. In case of meaning 1, replace the Fuser unit. 2. In case of meaning 3, replace the Engine contol board or Fuser control board or SMPS.
Display: Fuser error: #02-001. Please turn off then on
Description: 1. At warm up, the temperature keep up the lower temperature for regular time. 2. In case that the temperature has not reached warm up temperature after warm-up time. 3. At ready, Less than target temperature and for more than 10 sec. 4. At printing, Less than printing Ref. temp and for more than 10 sec.
Remedy: 1. Check the Thermostat. If it is defective, replace it. 2. Check the Lamp. If it is defective , replace it. 3. Check the fuser connector. Reconnect it. 4. In case of printer input voltage lower than standard voltage. 5. Check the Thermistor. 6. If the Heat On signal is not occurred from Power supply, replace it.
Display: Fuser error: #02-002. Please turn off then on
Description: 1. At warm up, the temperature keep up the lower temperature for regular time. 2. At warm up, after temperature checking time, more than regular temperature and for more 10 sec. 3. At standby or sleep, more than Top temp and for a few minutes. 4. At power save mode, the temperature keep up the constant for regular time.
Remedy: Replace Fuser or Fuser control board or Engine controller.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.