Display: System error: #02-003. Please turn off then on
Description: The communication error of the MEGA88 Micom
Remedy: 1. Open the side cover and close it. 2. Check the envelope pressing device.
Code: 03-006
Display: Motor does not operate: #03-006. Please turn off then on
Description: After Black OPC BLDC motor is operated, the ready signal is not occurred within 1 sec.
Remedy: Take out the toner cartridge and shake it horizontally. And re-install it.
Code: 04-000
Display: LSU error: #04-000. Please turn off then on
Description: LSU motor does not operate.
Remedy: After checking the LSU motor rotation noise, check the motor signal.
Code: 04-001
Display: LSU error: #04-001. Please turn off then on
Description: After LD on, the Laser beam detect signal is not occurred or irregular.
Remedy: 1. Check the Beam Detecht signal. If there is a BD signal, replace the Main board. If or not, check the LD contol signal. 2. Check the LD Power is normal. 3. If it is normal, check the light receving part.
Code: 04-002
Display: LSU error: #04-002. Please turn off then on
Description: LSU motor does not operate or the drive signal is abnormal.
Remedy: After checking the LSU motor rotation noise, check the motor signal.
Code: 06-006...06-007
Display: Toner cartridge: #06- 006...7. Please turn off then on
Description: Toner Cartridge Error
Remedy: Replace the toner cartridge.
Code: 06-013...06-16
Display: Imaging unit error: #06- 013...16. Please turn off then on
Description: Imaging unit error
Remedy: 1. Check the T/C sensor Harness connection. 2. Check the T/C sensor output wave. 3. Check the Engine B/D TC Sensor ADC
Code: 10-001
Display: Memory failure: #10-001. Please turn off then on
Description: At system booting, the memory is not read.