Remedy: Case 1 Cause EEPROM trouble, Insertion of EEPROM which is not initialized or defective. Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause PCU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the PCU PWB. 3. Use SIM 16 to cancel the error.
Description: Adjustment value check sum error (PCU)
Causes: EEPROM (PCU) check sum error
Remedy: Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause Control circuit freeze caused by noises, PCU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the PCU PWB. 3. Use SIM 16 to cancel the error.
Causes: The alignment plate does not move from the home position within 1sec when it must move. Return to the home position is not detected for 5sec or more.
Remedy: Case 1 Cause Home position sensor trouble Check & Remedy Use SIM 9-2 to detect the home position sensor. Case 2 Cause Alignment plate shift motor trouble Check & Remedy Use SIM 9-4 to check the alignment plate operation. Case 3 Cause Disconnection of the harness between the ADU control PWB and the motor sensor. Check & Remedy Check connection of the harness between the ADU control PWB and the motor sensor. Case 4 Cause Alignment plate operation belt, gear breakage or improper adjustment Check & Remedy Remove the ADU, and check for breakage of the gear and the belt.
Causes: Communication test error when turning on the power or after canceling the exclusive simulation. Communication error with the ADF
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause ADF control PWB trouble, control PWB (MFP) trouble, malfunction caused by noises Check & Remedy Check the ADF control PWB and the control PWB (MFP). Turn OFF/ON the power to cancel the error.
Remedy: Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Causes: ADF paper feed/reverse sensor detection trouble
Remedy: Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Remedy: Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Description: Paper feed motor operation abnormality
Causes: Paper feed motor operation abnormality
Remedy: Case 1 Cause Motor lock, motor RPM abnormality, Over current to the motor, ADF control PWB trouble Check & Remedy Use SIM 2-2/3/4 to check the paper feed motor operation.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.