Causes: Desk communication error, communication test error when turning on the power or after canceling the exclusive simulation.
Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness. Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause Desk control PWB trouble, control PWB (PCU) trouble, malfunction caused by noises Check & Remedy Turn OFF/ON the power to cancel the error.
Code: U6 01
Description: Desk tray 1 lift motor trouble
Causes: DLUD1 does not turn on within the specified time.
Remedy: Case 1 Cause DLUD1 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD1 and the harness and the connector. Case 2 Cause Cassette 1 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.
Code: U6 02
Description: Desk tray 2 lift motor trouble
Causes: DLUD2 does not turn on within the specified time.
Remedy: Case 1 Cause DLUD2 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD2 and the harness and the connector. Case 2 Cause Desk cassette 2 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.
Code: U6 03
Description: Desk tray 3 lift motor trouble
Causes: DLUD3 does not turn on within the specified time.
Remedy: Case 1 Cause DLUD3 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD3 and the harness and the connector. Case 2 Cause Desk cassette 3 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.
Code: U6 09
Description: LCC lift motor trouble
Causes: • The encoder input value does not change in 0.13sec (first time)/0.5sec (second time or later) after rotation of the motor. • The motor is rotated for 18sec or more. • The encoder changes after the specified time from termination of the motor. (2sec and 10 counts or more)
Remedy: Common Check Use SIM 4-2 and 4-3 to check the sensor operation and the lift motor operation. Cancel the trouble with SIM 15. Case 1 Cause Sensor trouble Check & Remedy Replace the sensor. Case 2 Cause LCC control PWB trouble Check & Remedy Replace the LCC control PWB. Case 3 Cause Gear breakage Check & Remedy Replace the gear. Case 4 Cause Lift motor trouble Check & Remedy Replace the lift motor.
Code: U6 10
Description: Desk transport motor trouble
Causes: Desk transport motor operation trouble
Remedy: Case 1 Cause Motor lock, motor RPM abnormality, Over current to the motor, saddle finisher control PWB trouble Check & Remedy Use SIM 4-3 to check the desk transport motor operation.
Code: U6 20
Description: LCC communication trouble
Causes: Communication error with the LCC. Communication line test error after turning on the power or canceling an exclusive simulation. Discrepancy of the model code between the LCC and the machine.
Remedy: Common Turn OFF/ON the power to cancel the error. Case 1 Cause Improper connection or disconnection of the connector and the harness. Check & Remedy Check the connector and the harness in the communication line. Case 2 Cause LCC control PWB trouble Check & Remedy Replace the LCC control PWB. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the control PWB (PCU). Case 4 Cause Malfunction caused by noises Check & Remedy Turn OFF/ON the power to cancel the error.
Code: U6 21
Description: LCC transport motor trouble
Causes: • The encoder input value does not change in 0.06sec after turning on the motor. • The encoder input changes after the specified time from turning off the motor. (100 or more counts are made in 0.1sec after 5sec.)
Remedy: Case 1 Cause Motor lock, motor RPM abnormality. Over current to the motor, saddle finisher control PWB trouble Check & Remedy Use SIM 4-3 to check the transport motor operation.