Các lỗi thường gặp

Code :
  • Code: F2 73
  • Description: Developing unit improper cartridge detection (Yellow)
  • Causes: When detecting the normal CRUM of the cartridge, improper data are detected in the CRUM contents.
  • Remedy: Case 1 Cause Insertion of an improper cartridge. Developing unit trouble Check & Remedy Replace the developing unit.
  • Code: F2 74
  • Description: Developing unit CRUM trouble (Black)
  • Causes: CRUM read/write error
  • Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
  • Code: F2 75
  • Description: Developing unit CRUM trouble (Cyan)
  • Causes: CRUM read/write error
  • Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
  • Code: F2 76
  • Description: Developing unit CRUM trouble (Magenta)
  • Causes: CRUM read/write error
  • Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
  • Code: F2 77
  • Description: Developing unit CRUM trouble (Yellow)
  • Causes: CRUM read/write error
  • Remedy: Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
  • Code: F2 78
  • Description: Trouble of image density sensor for registration (Transfer belt surface reflection ratio abnormality)
  • Causes: Before starting registration, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the value is not within the specified range.
  • Remedy: Case 1 Cause Image density sensor trouble, disconnection of the harness between the PCU PWB and the image density sensor, dirt on the image density sensor. Check & Remedy Check the sensor and the harness. Case 2 Cause Calibration plate solenoid operation trouble Check & Remedy Check the calibration plate solenoid operation. Case 3 Cause Insufficient cleaning of the transfer belt. Check & Remedy Check the transfer belt surface.
  • Code: F2 80
  • Description: Half-tone process control 1st batch trouble (Black)
  • Causes: First step operation error during half-tone process control
  • Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
  • Code: F2 81
  • Description: Half-tone process control 1st batch trouble (Cyan)
  • Causes: First step operation error during half-tone process control
  • Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.