Code: 952

Description: NV failure:n
Remedy: Recoverable error. Reset (POR) the printer.

Code: 953

Description: NVRAM chip failure
Remedy: Indicates the NVRAM chip has failed. Replace the controller card.

Code: 954

Description: NVRAM CRC failure
Remedy: Indicates the NVRAM experienced a CRC failure. Replace the controller card.

Code: 955

Description: Code CRC <loc>
Remedy: Replace the controller card. Where <loc> = CRC Failure or ECC Failure on the controller card.

Code: 956

Description: Controller card
Remedy: Error codes 956, 957, and 959 are controller card failures. Perform a power on reset (POR). If this does not fix the problem, replace the controller card.

Code: 957

Description: ASIC failure
Remedy: Error codes 956, 957, and 959 are controller card failures. Perform a power on reset (POR). If this does not fix the problem, replace the controller card.

Code: 958

Description: NAND failure
Remedy: Before proceeding, perform a power on reset (POR) to see if the ECC error correction code can reflash NAND. If this does not fix the problem, replace the controller card.

Code: 959

Description: SRAM failure
Remedy: Error codes 956, 957, and 959 are controller card failures. Perform a power on reset (POR). If this does not fix the problem, replace the controller card.