Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 320P — Trang 2/5

Code: 920

Description: Fuser error
Remedy: Indicates that the fuser is below temperature when printing.

Code: 922

Description: Fuser error
Remedy: Fuser failed to reach standby temperature. Verify line voltage to the fuser

Code: 923

Description: Fuser error
Remedy: Fuser is too hot during printing or when printer is idle

Code: 924

Description: Fuser error
Remedy: An open circuit has been detected in the fuser thermistor circuit. Check cabling and connectors.

Code: 929

Description: Toner sensor
Remedy: The toner sensor is not operating properly, the developer drive assembly is not operating properly, or the print cartridge is defective.

Code: 931

Description: Printhead - no first hysnc
Remedy: Check for unplugged printhead, faulty cabling, or faulty printhead.

Code: 932

Description: Printhead—lost hsyncs
Remedy: Replace the printhead.

Code: 934

Description: Mirror motor lost lock
Remedy: Replace the printhead.