Description: Punch power failure abnormality: 24 V is not applied to the punch controller board. [MJ-1025 (when MJ-6005 is installed)]
Remedy: MJ-1025 Is the problem solved by turning the power of the equipment OFF and ON? YES End NO Is the wiring between the finisher controller PC board and punch controller PC board correct? NO Correct the wiring. YES Does the voltage between the CN14-5 (+) and CN14-3 (-) on the finisher controller PC board become 24 V? YES Replace the punch controller PC board. NO Replace the finisher controller PC board.
Code: CDD0
Description: Folding position sensor abnormality: Automatic adjustment of the folding position sensor can not be performed properly. [MJ-1025]
Remedy: MJ-1025 Is the folding position sensor (PI10) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and folding position sensor (PI10) correct? NO Correct the wiring. YES Is there any mechanical problem with the fold jam releasing dial? YES Fix the mechanism. NO 1. Replace the staple/fold motor (M7). 2. Replace the finisher controller PC board.
Code: CDE0
Description: Paddle motor abnormality: The paddle motor does not rotate properly. [MJ-1025]
Remedy: MJ-1025 Is the paddle home position sensor (PI2) working properly? NO Replace the sensor. YES Is the Swing guide home position sensor (PI3) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and Paddle motor (M2) correct? NO Correct the wiring. YES Try to rotate the paddle motor (M2) clockwise and counterclockwise by hand. Is there mechanical trapping in the rotation of the paddle or the up/down movement of the swing guide? YES Fix the mechanism. NO 1. Replace the paddle motor (M2) 2. Replace the finisher controller PC board. the initial operation. MJ-1101 Is there any mechanical problem with the paddle is rotated? ..YES Fix the mechanism. NO Is the harness between the paddle motor (M8) and the finisher control PC board (CN6) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO 1. Replace the paddle motor (M8). 2. Replace the finisher control PC board.
Code: CDF0
Description: Initialization error of the offset tray: The home position of the separator cannot be detected when the power is turned ON.
Remedy: (1) Check if each connector between the offset gate motor and MOT2 board (CN406) is disconnected. (2) Check if each connector between the MOT2 board (CN406) and LGC board (CN302) is disconnected. (3) Check if each connector pin is removed or the harness is broken. (4) Check if any conductor pattern on the MOT2 board and LGC board is short circuited or open circuited. (5) Replace the offset gate motor. (6) Replace the MOT2 board. (7) Replace the LGC board.
Code: CE00
Description: Communication error between finisher unit and puncher unit: Communication error between the finisher controller PC board and punch controller PC board. [MJ-1025 (when MJ-6005 is installed)] Communication error between finisher and punch unit: Communication error between finisher controller PC board and punch controller PC board [MJ-1024 (when MJ-6004 is installed)] [MJ-1101 (when MJ-6101 is installed)]
Remedy: MJ-1025 (when MJ-6005 is installed) Is the problem solved by turning the power of the equipment OFF and ON? YES End. NO Is the wiring between the finisher controller PC board and the punch controller PC board correct? NO Correct the wiring. YES Measure the voltage between CN14-5 (+) and CN14-3 (-) on the finisher controller PC board 24 V? NO Replace the finisher controller PC board. YES Replace the punch controller PC board. MJ-1024 (When MJ-6004 is installed) Is the problem solved by turning OFF and ON the power of the equipment? YES.. End. NO Is the wiring between the finisher controller PC board and punch controller PC board correct? NO Correct the wiring. YES 1. Replace the finisher controller PC board. 2. Replace the punch controller PC board. MJ-1101 (When MJ-6101 is installed) Is the harness between the hole punch control PC board (HP) and the finisher control PC board disconnected or open circuited? ..YES Replace the harness. Correct the wiring. NO Is the conductor pattern on the hole punch control PC board (HP) open circuited or short circuited? ..YES Replace the hole punch control PC board (HP). NO Replace the finisher control PC board.
Code: CE50
Description: Temperature/humidity sensor abnormality: The output value of this sensor is out of a specified range.
Remedy: MJ-1025 (when MJ-6005 is installed) Is the problem solved by turning the power of the equipment OFF and ON? YES End. NO Is the wiring between the finisher controller PC board and the punch controller PC board correct? NO Correct the wiring. YES Measure the voltage between CN14-5 (+) and CN14-3 (-) on the finisher controller PC board 24 V? NO Replace the finisher controller PC board. YES Replace the punch controller PC board. MJ-1024 (When MJ-6004 is installed) Is the problem solved by turning OFF and ON the power of the equipment? YES.. End. NO Is the wiring between the finisher controller PC board and punch controller PC board correct? NO Correct the wiring. YES 1. Replace the finisher controller PC board. 2. Replace the punch controller PC board. MJ-1101 (When MJ-6101 is installed) Is the harness between the hole punch control PC board (HP) and the finisher control PC board disconnected or open circuited? ..YES Replace the harness. Correct the wiring. NO Is the conductor pattern on the hole punch control PC board (HP) open circuited or short circuited? ..YES Replace the hole punch control PC board (HP). NO Replace the finisher control PC board.
Code: CE90
Description: Drum thermistor abnormality: The output value of the drum thermistor-K is out of a specified range.
Remedy: MJ-1025 (when MJ-6005 is installed) Is the problem solved by turning the power of the equipment OFF and ON? YES End. NO Is the wiring between the finisher controller PC board and the punch controller PC board correct? NO Correct the wiring. YES Measure the voltage between CN14-5 (+) and CN14-3 (-) on the finisher controller PC board 24 V? NO Replace the finisher controller PC board. YES Replace the punch controller PC board. MJ-1024 (When MJ-6004 is installed) Is the problem solved by turning OFF and ON the power of the equipment? YES.. End. NO Is the wiring between the finisher controller PC board and punch controller PC board correct? NO Correct the wiring. YES 1. Replace the finisher controller PC board. 2. Replace the punch controller PC board. MJ-1101 (When MJ-6101 is installed) Is the harness between the hole punch control PC board (HP) and the finisher control PC board disconnected or open circuited? ..YES Replace the harness. Correct the wiring. NO Is the conductor pattern on the hole punch control PC board (HP) open circuited or short circuited? ..YES Replace the hole punch control PC board (HP). NO Replace the finisher control PC board.
Code: CF10
Description: Communication module SRAM reading failure. [MJ-1101]
Remedy: MJ-1101 1. Is the error recovered when the power of the equipment is turned OFF and then back ON? 2. Check if the MJ-1101 is set as the specified finisher on the equipment. 3. Check if the harness connecting the converter PC board and the finisher controller PC board is disconnected or open circuited. 4. Check if the conductor pattern on the converter PC board is open circuited or short circuited. 5. Check if the conductor pattern on the finisher controller PC board is open circuited or short circuited. 6. Replace the converter PC board. 7. Replace the finisher control PC board. MJ-1101 (When MJ-6101 is installed) 1. Is the error recovered when the power of the equipment is turned OFF and then back ON? 2. Check if the MJ-1101 is set as the specified finisher on the equipment. 3. Check if the harness connecting the converter PC board and the finisher controller PC board is disconnected or open circuited. 4. Check if the harness connecting the hole punch control PC board and the finisher control PC board is disconnected or open circuited. 5. Check if the conductor pattern on the converter PC board is open circuited or short circuited. 6. Check if the conductor pattern on the finisher controller PC board is open circuited or short circuited. 7. Check if the conductor pattern on the hole punch control PC board is open circuited or short circuited. 8. Replace the converter PC board. 9. Replace the finisher control PC board. 10.Replace the hole punch control PC board.