Các lỗi thường gặp

Code :
  • Code: 17-200-00
  • Description: Network Cable Disconnected
  • Causes: Network cable is not connected.
  • Remedy: • Check the network connection. NOTE: The network connection has two LEDs The green LED on indicates that the network connection is ready. The amber LED flashing indicates that the network is good.
    Reseat the network cable to the IP Board.
  • Code: 17-700-00, 17-710-00
  • Description: BOOTP Server Error
  • Causes: 17-700-00 BOOTP and auto IP is not working. 17-710-00 BOOTP and auto IP is not working.
  • Remedy: • Check BOOTP configuration. • Check network configuration.
    Cycle system power.
  • Code: 17-800-00, 17-810-00
  • Description: DHCP Server Error
  • Causes: 17-800-00 DHCP and auto IP is not working. 17-810-00 DHCP and auto IP is not working.
  • Remedy: • Check DHCP settings. • Check network configuration.
    Cycle system power.
  • Code: 17-900-00
  • Description: 802.1X Authentication Error
  • Causes: 802.1X Authentication failed.
  • Remedy: • Close the Rear Door. • Check for obstructions blocking the latch.
    Ensure that the 802.1X EAP type, user name and password for the machine authentication switch and authentication server match.
  • Code: 17-910-00
  • Description: irmware Upgrade Fault
  • Causes: Upgrade aborted invalid file.
  • Remedy: • Download a new firmware file. • Check the USB connection
    Cycle system power and repeat the upgrade procedure.