Mã lỗi Xerox Phaser 840 — Trang 2/13

Code: 07,005.47

Display: 07,005.47 PM_FAULT_DM_CAM_ POSITION_ERROR
Description: The Drum Maintenance home sensor actuated, but not at the expected time. Inspect the maintenance drawer lift pins for wear. Run diagnostics to verify clutch and sensor operation. Also verify that the drum maintenance shaft is properly assembled.

Code: 07,006.48

Display: 07,006.48 PM_FAULT_DM_CAM UNEXPECTED_MOTION
Description: The Drum Maintenance home sensor actuated, when no motion should have occurred. Run diagnostics to verify clutch and sensor operation. Also verify that the shaft is properly assembled.

Code: 08,001.44

Display: 08,001.44: CAP_FAULT_HOME_ SENSOR
Description: The cap-home sensor did not see the sensor’s flag when expected. The home sensor may be faulty, or the paper- feed motor may not be operating. The cap/wipe/purge clutch may be failing, or the assembly may be jammed and unable to move. Inspect check the paper-exit drive belt and the gear on the right end of the duplex roller shaft next to the paper path motor. Ensure that the paper path is free of media. For the Phaser 860 only, run the Cap Axis Geometry and Cap Axis Drive diagnostic tests.

Code: 08,003.46

Display: 08,003.46
Description: The cap-home sensor was activated too soon. This can occur if the cap/wipe/purge assembly was obstructed while moving up and therefore retruned to the home position too soon. Ensure that the head tilt mechanism is working properly. Run diagnostics to verify cap drive motion and alignment.

Code: 08,009.65

Display: 08,009.65
Description: An unexpected message was received while homing the Cap/Wipe/Purge assembly, usually during system initialization. This fault is due to a failure of the Y-Axis Encoder

Code: 09,009.44

Display: 09,009.44 IL_FAULT_INK_UNPLUG
Description: Ink well sense cable on the printhead appears to be unplugged.

Code: 11,001.60

Display: 11,001.60 DMC_PROG_FAULT(1)
Description: Timer Event Missed. A health check routine is called every 400 milliseconds, the A/D update period, and checks that all the currently pending timer events are for some time in the future. It generates this error if it detects a timer event for some time in the past. A missed DMC interrupt, due to interrupts disabled too long by any region, is the probable cause.

Code: 11,007.66

Display: 11,007.66 DMC_PROG_FAULT(7)
Description: Event parameter Block not Prepped. The parameter block associated with a DMC event notification was not prepped with a call to dmc_prep_event_parm_block() before the call to dmc_request_event_notification().