Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Xerox Phaser 840 — Trang 12/13

Code: 6,001.42

Display: 6,001.42
Description: Indication that the motor coil(s) is open or shorted, or the X-axis motor fuse has opened. Follow the procedure "Testing motor and solenoid resistances", on page 84 of this manual. Try diagnostics to verify X-axis movement. If there is not any movement, it is propable that the fuse is defective. The fuse is located in the power control board; the whole baord should be replaced.

Code: 6,002.43

Display: 6,002.43
Description: Indication that the motor coil(s) is open or shorted, or the X-axis motor fuse has opened. Follow the procedure "Testing motor and solenoid resistances", on page 84 of this manual. Try diagnostics to verify X-axis movement. If there is not any movement, it is propable that the fuse is defective. The fuse is located in the power control board; the whole baord should be replaced.

Code: 6,003.44

Display: 6,003.44
Description: Indication that the motor coil(s) is open or shorted, or the X-axis motor fuse has opened. Follow the procedure "Testing motor and solenoid resistances", on page 84 of this manual. Try diagnostics to verify X-axis movement. If there is not any movement, it is propable that the fuse is defective. The fuse is located in the power control board; the whole baord should be replaced.

Code: 6,033.66

Display: 6,033.66 XA_PROGFAULT_X6
Description: XA Unexpected Message. The XA task received an unexpected ITC message while in the idle state.

Code: 7,035.63

Display: 7,035.63: PM_PROG_FAULT_ FUNCS(3)
Description: Negative delay in pm_sleep_for(). A negative delay argument was passed to pm_sleep_for().

Code: 7,036.64

Display: 7,036.64: PM_PROG_FAULT_ FUNCS(4)
Description: Unexpected message in pm_sleep_for(). An unexpected ITC message was received by pm_get_message() during processing of pm_sleep_for().

Code: 7,052.62

Display: 7,052.62: PM_PROG_FAULT_ FUNCS(20)
Description: Bad message ID in pm_update_dmc_status(). The ITC message received and passed to pm_update_dmc status() did not match any DMC status message that the Process Motor task was expecting.

Code: 8,002.67

Display: 8,002.67 CAP_PROG_FAULT(22)
Description: Generic Cap Task Program Fault. This error indicates that the main CAP state sequencer, cap_main(), has entered the program fault state. There are multiple reasons that this can happen. Genereally they involve unexpected conditions while performing CAP movements; home, goto, etc.