Description: IOT Zone T3 + T4 + TR3 Jam 050-136 is displayed in the UI. 072-101 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-101 IOT Path2 SNS On Jam When Static Jam (collateral) was detected: • Tray3 Path Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to FIP 1. 277.
Code: 050-137
Description: IOT Zone T2 + T3 + TR2 + TR3 Jam 050-137 is displayed in the UI. 072-102 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-102 IOT Option Regi On Jam When Static Jam (collateral) was detected: • Tray2 Path Sensor On and Tray3 Path Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to FIP 1. 278.
Code: 050-138
Description: 050-138 IOT Zone T3 + TR2 + TR3 Jam 050-138 is displayed in the UI. 072-102 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-102 IOT Option Regi On Jam When Static Jam (collateral) was detected: • Tray3 Path Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 278.
Code: 050-139
Description: IOT Zone T2 + TR2 Jam 050-139 is displayed in the UI. 072-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-100 IOT Tray2 Misfeed Jam When Static Jam (collateral) was detected: • Tray2 Path Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
Code: 050-140
Description: IOT Zone T3 + TR2 Jam 050-140 is displayed in the UI. 073-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 073-100 IOT Tray3 Misfeed Jam
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
Code: 050-141
Description: IOT Zone T4 + TR3 Jam 050-141 is displayed in the UI. 074-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 074-100 IOT Tray4 Misfeed Jam When Static Jam (collateral) was detected: • Tray4 Path Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
Code: 050-142
Description: IOT Remain Zone Regi + MSI + T1 Jam 050-142 is displayed in the UI. 077-106 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 077-106 Exit On Jam When Static Jam (collateral) was detected: • Regi Sensor On
Remedy: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 284.
Code: 061-370
Description: IOT ROS Failure Cause: The operation error of ROS (rotational error etc.) is detected.
Remedy: 1 Check the connections between the ROS ASSEMBLY and the MCU PWB, as well as between the ROS ASSEMBLY and the ESS PWB. • Are the ROS-MCU HARNESS (P/J501- P/J19), ROS ASSEMBLY (P/J18), and the VIDEO HARNESS (P/J502 - P/J322) connected securely? Go to Step 2. Securely connect the ROS-MCU HARNESS, ROS ASSEMBLY and the VIDEO HARNESS 2 • Replace (ROS Assembly). • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace (MCU PWB). • Does an error occur? Replace (ESS PWB) Troubleshooting complete.