Description: Feed Out Sensor 4 Static Jam Feed Out Sensor 4 On was detected during Standby.
Remedy: Check the following: • The Feed Out Sensor 4 for remaining paper, Actuator return failure, foreign substances, contamination on sensor, and etc. • Feed Out Sensor 4: Input Check [072-112] (PL 11.5) If no problems are found, replace the 2TM PWB (PL 11.6).
Description: Drum Cartridge Quality Life Over/ Drum Cartridge Life Over [Drum Cartridge Quality Life Over] The image quality guarantee period for the Drum Cartridge has ended. (When Drum Hard Stop-less is enabled) [Drum Cartridge Life Over] When in Life Extension Mode, the Drum Cartridge was detected to be near the end of its life span
Remedy: Replace the Drum Cartridge. (PL 8.1) NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to '0'.
Description: Drum Cartridge Normal Life Over/ Drum Cartridge Abnormal Life Over [Drum Cartridge Normal Life Over] The operation guarantee period for the Drum Cartridge has ended. (When Drum Hard Stopless is enabled) [Drum Cartridge Abnormal Life Over] The Drum Cartridge is out of warranty and this could result in a malfunction of the machine. (When Drum Hard Stop-less is enabled)
Remedy: Replace the Drum Cartridge. (PL 8.1) NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to '0'.
Description: Drum Cartridge Pre Near End Preparation for replacing the Drum Cartridge is required.
Remedy: The Drum Cartridge needs to be replaced soon. Prepare a new Drum Cartridge. Replace the Drum Cartridge as required. (PL 8.1) NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to '0'.
Description: Drum Cartridge Near End The Drum Cartridge needs to be replaced soon.
Remedy: The Drum Cartridge needs to be replaced soon. Replace the Drum Cartridge as required. (PL 8.1) NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to '0'.
Description: ATC Amplitude Fail/ ATC Average Fail [ATC Amplitude Fail] The output amplitude of the ATC Sensor in the ATC (Automatic Toner Control) measurement is small. [ATC Average Fail] The average output value is not within the specified range in the ATC (Automatic Toner Control) measurement.
Remedy: 1. Install a Toner Cartridge that contains Toner. Copy a Test Chart (499T247), etc. and check whether the density has recovered. 2. Check the Toner Dispense Motor (Output Check [092-001]) for operation failure. (PL 8.2) 3. Check the Toner transport path for Toner blockage. 4. Check the connection between the ATC Sensor P615 and the ESS/MCU PWB J409 for open circuit, short circuit, and poor contact. 5. If no problem is found, replace the following parts in sequence: • ATC Sensor (PL 8.6) • Developer Unit (PL 8.4) • Drum Cartridge (PL 8.1) NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to '0'. • ESS/MCU PWB (PL 18.3)
Description: Temperature Sensor Fail The output value of the Temperature Sensor is not within the specification range.
Remedy: 1. Turn the power OFF and ON. 2. Check the connection between the HVPS J500-1 and the ESS/MCU PWB J402-14 for open circuit, short circuit, and poor contact. 3. If no problem is found, replace the following parts in sequence: • HVPS (PL 18.3) • ESS/MCU PWB (PL 18.3)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.