  • Code: 116-321
  • Description: Controller Logic Fail • A software defect that cannot be ignored was found in the Controller software. • The CPU has rebooted due to the occurrence of an exception.
  • Remedy: 1. Turn the power OFF and ON. 2. Install a Controller Firmware with the correct version.
  • Code: 116-323
  • Description: Controller NVM Data Defect Any of the following was detected: • The On Board NVM data of the Controller is corrupted. • The On Board NVM of the Controller is not installed. • Any one of the Print Counter has reached its maximum value. • The number of times the NVM can be changed has reached its limit. NOTE: If this Fault reoccurs after performing Data Backup/Restore, perform Data Restore again. (Perform NVM Matching (NVM [621-400]) in the CE Mode.)
  • Remedy: 1. Turn the power OFF and ON. 2. Perform NVM Initialize in the CE Mode. (Refer to 6.5.2.4 NVM Initialize)
  • Code: 116-324
  • Description: Exception Fail The CPU has rebooted due to the occurrence of an exception.
  • Remedy: Upgrade the Controller software or contact the Support Department.
  • Code: 116-334
  • Description: NVM Data Mismatch The verification result between the On Board NVM and the Backup NVM of the Controller is mismatched. (This includes cases where one of the NVM is Blank)
  • Remedy: 1. Turn the power OFF and ON. 2. Perform NVM Matching (NVM [621-400]) in the CE Mode.
  • Code: 116-377
  • Description: IIT Interrupt Timeout The DMA start trigger when scanning documents cannot be detected for a specified time.
  • Remedy: 1. Turn the power OFF and ON. 2. Turn OFF the power and check the Flat Cable between the IIT Carriage J700 and the ESS/MCU PWB J420 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). 3. Check the ESS/MCU PWB for improper installation (loose screw). 4. Upgrade the Controller Firmware. ADJ 18.2.3 5. If no problem is found, replace the ESS/MCU PWB (PL 18.3).
  • Code: 116-386
  • Description: USB Host Terminal Unknown Device Connection Fail It was detected that something other than a Fax Board is inserted into the USB Host Terminal.
  • Remedy: 1. Turn the power OFF and ON. 2. Connect the correct Fax PWB (PL 18.5).
  • Code: 116-747
  • Description: Invalid Page Margin During Copy Job, subtracting the amount of edge erase from the section that should have been scanned resulted in a negative value.
  • Remedy: Change the value for NVM [790-301] (Document Edge Erase Amount) or NVM [790-302] (Document Edge Erase Amount (for ID Card Copy)).
  • Code: 117-327
  • Description: Controller Extension Card NVM Data Defect Any of the following was detected: • The NVM data of the NET I/F Card is corrupted. • The NVM of the NET I/F Card is not installed
  • Remedy: 1. Turn the power OFF and ON. 2. Check whether the EEPROM is installed. 3. Check the EEPROM for poor contact with the socket. 4. Check the connector ( P/J425) between the ESS/MCU PWB and the NET I/F PWB for poor contact. 5. If no problem is found, replace the following parts in sequence: • NET I/F PWB (PL 18.3) • ESS/MCU PWB (PL 18.3)