Description: Size Mismatch Jam on Mix-size RAP In Mixed Size Originals, it was detected that the Fast Scan Direction size was different from the width of the document guide.
Remedy: Execute Component Control[005-221]. Actuate the DADF Tray Size 1 Sensor with paper. The display changes. Y↓N→Check the connections of P/J771 and P/J759. P/J771 and P/J759 are connected correctly. Y↓N→Connect P/J771 and P/J759. Check the wire between J771 and J759 for an open circuit or a short circuit. The wire between J771 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-2 (+) and GND (-). Actuate the DADF Tray Size 1 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 1 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Execute Component Control[005-222]. Actuate the DADF Tray Size 2 Sensor with paper. The display changes. Y↓N→Check the connections of P/J772 and P/J759. P/J772 and P/J759 are connected correctly. Y↓N→Connect P/J772 and P/J759. Check the wire between J772 and J759 for an open circuit or a short circuit. The wire between J772 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-5 (+) and GND (-). Actuate the DADF Tray Size 2 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 2 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Code: 005-196
Description: CVT Size Mismatch JAM (No Mix) RAP The second and subsequent documents are different size to the first document.
Remedy: Execute Component Control[005-221]. Actuate the DADF Tray Size 1 Sensor with paper. The display changes. Y↓N→Check the connections of P/J771 and P/J759. P/J771 and P/J759 are connected correctly. Y↓N→Connect P/J771 and P/J759. Check the wire between J771 and J759 for an open circuit or a short circuit. The wire between J771 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-2 (+) and GND (-). Actuate the DADF Tray Size 1 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 1 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Execute Component Control[005-222]. Actuate the DADF Tray Size 2 Sensor with paper. The display changes. Y↓N→Check the connections of P/J772 and P/J759. P/J772 and P/J759 are connected correctly. Y↓N→Connect P/J772 and P/J759. Check the wire between J772 and J759 for an open circuit or a short circuit. The wire between J772 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-5 (+) and GND (-). Actuate the DADF Tray Size 2 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 2 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Code: 005-197
Description: 005-197 Prohibit Combine Size JAM RAP A prohibited size combination was detected.
Remedy: Execute Component Control[005-221]. Actuate the DADF Tray Size 1 Sensor with paper. The display changes. Y↓N→Check the connections of P/J771 and P/J759. P/J771 and P/J759 are connected correctly. Y↓N→Connect P/J771 and P/J759. Check the wire between J771 and J759 for an open circuit or a short circuit. The wire between J771 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-3 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-2 (+) and GND (-). Actuate the DADF Tray Size 1 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 1 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Execute Component Control[005-222]. Actuate the DADF Tray Size 2 Sensor with paper. The display changes. Y↓N→Check the connections of P/J772 and P/J759. P/J772 and P/J759 are connected correctly. Y↓N→Connect P/J772 and P/J759. Check the wire between J772 and J759 for an open circuit or a short circuit. The wire between J772 and J759 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P759-6 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P759-5 (+) and GND (-). Actuate the DADF Tray Size 2 Sensor with paper. The voltage changes. Y↓N→Replace the DADF Tray Size 2 Sensor (PL 15.10). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Code: 005-198
Description: Too Short Size JAM RAP The system detected a document with a length shorter than 115mm in the Slow Scan Direction.
Remedy: Check the document size. The size of the document is within the specification. Y↓N→Use a paper size within the specification. Execute Component Control[005-205]. Actuate the DADF Feed Out Sensor (PL 15.9) with paper. The display changes. Y↓N→Check the connections of P/J769 and P/J758. P/J769 and P/J758 are connected correctly. Y↓N→Connect P/J769 and P/J758. Check the wire between J769 and J758 for an open circuit or a short circuit. The wire between J769 and J758 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P758-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P758-3 (+) and GND (-). Actuate the DADF Feed Out Sensor with paper. The voltage changes. Y↓N→Replace the DADF Feed Out Sensor (PL 15.9). Replace the DADF PWB (PL 15.3). Execute Component Control[005-206]. Actuate the DADF Pre Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J781 and P/J761. P/J781 and P/J761 are connected correctly. Y↓N→Connect P/J781 and P/J761. Check the wire between J781 and J761 for an open circuit or a short circuit. The wire between J781 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-12 (+) and GND (-). Actuate the DADF Pre Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Pre Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Code: 005-199
Description: Too Long Size JAM RAP The system detected a document with the following length in the Slow Scan Direction: • Simplex mode: 672.4mm or longer • Duplex mode: 480.1mm or longer
Remedy: Check the document size. The size of the document is within the specification. Y↓N→Use a paper size within the specification. Check the Transport Roll for wear and paper powder. The Transport Roll is ok. Y↓N→Replace the Transport Roll. Check for foreign substances, distortion and paper powder in the paper transport path. No distortion, foreign substances, or paper powder are found in the paper transport path. Y↓N→Clear away the foreign substances and paper powder. Correct the distortion. Execute Component Control[005-205]. Actuate the DADF Feed Out Sensor (PL 15.9) with paper. The display changes. Y↓N→Check the connections of P/J769 and P/J758. P/J769 and P/J758 are connected correctly. Y↓N→Connect P/J769 and P/J758. Check the wire between J769 and J758 for an open circuit or a short circuit. The wire between J769 and J758 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P758-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P758-3 (+) and GND (-). Actuate the DADF Feed Out Sensor with paper. The voltage changes. Y↓N→Replace the DADF Feed Out Sensor (PL 15.9). Replace the DADF PWB (PL 15.3). Execute Component Control[005-206]. Actuate the DADF Pre Registration Sensor (PL 15.7) with paper. The display changes. Check the connections of P/J781 and P/J761. P/J781 and P/J761 are connected correctly. Y↓N→Connect P/J781 and P/J761. Check the wire between J781 and J761 for an open circuit or a short circuit. The wire between J781 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-12 (+) and GND (-). Actuate the DADF Pre Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Pre Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
Code: 005-275
Description: DADF ROM Download Error There is a download error in the DADF ROM PWB.
Remedy: Switch off the power. Ensure the ROM is properly installed in the DADF PWB. Switch on the power. If the problem persists, replace the DADF PWB (PL 15.3).
Code: 005-275
Description: DADF Error There is a processing error in the DADF PWB.
Remedy: Switch off the power. Disconnect and reconnect the P/Js on the DADF PWB. Switch on the power. If the problem persists, replace the DADF PWB (PL 15.3).
Code: 005-280
Description: DADF EPROM Failure RAP The DADF-EEPROM failed during the Read/Write operation.
Remedy: Check the connection of each DADF PWB connector. The connectors are connected correctly. Y↓N→Connect the connectors. Turn on the power again. [005-280] reoccurs. Y↓N→Return to Service Call Procedures. Replace the DADF PWB (PL 15.3).