Các lỗi thường gặp

Code :
  • Code: 005-915
  • Description: CVT APS No1 Sensor Static JAM RAP Paper remains on the APS Sensor 1.
  • Remedy: Execute Component Control[005-218 DADF APS 1 Sensor]. Actuate the DADF APS 1 Sensor with paper. The display changes. Y↓N→Check the connections of P/J777 and P/J761. P/J777 and P/J761 are connected correctly. Y↓N→Connect P/J777 and P/J761. Check the wire between J777 and J761 for an open circuit or a short circuit. The wire between J777 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-4 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-6 (+) and GND (-). Actuate the DADF APS 1 Sensor with paper. The voltage changes. Y↓N→Replace the DADF APS 1 Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 005-916
  • Description: CVT APS No2 Sensor Static JAM RAP Paper remains on the APS Sensor 2.
  • Remedy: Execute Component Control[005-219 DADF APS 2 Sensor]]. Actuate the DADF APS 2 Sensor with paper. The display changes. Y↓N→Check the connections of P/J778 and P/J761. P/J778 and P/J761 are connected correctly. Y↓N→Connect P/J778 and P/J761. Check the wire between J778 and J761 for an open circuit or a short circuit. The wire between J778 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-3 (+) and GND (-). Actuate the DADF APS 2 Sensor with paper. The voltage changes. Y↓N→Replace the DADF APS 2 Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 005-917
  • Description: CVT APS No3 Sensor Static JAM RAP Paper remains on the APS Sensor 3.
  • Remedy: Execute Component Control[005-220 DADF APS 3 Sensor]]. Actuate the DADF APS 3 Sensor with paper. The display changes. Y↓N→Check the connections of P/J779 and P/J785. P/J779 and P/J785 are connected correctly. Y↓N→Connect P/J779 and P/J785. Check the wire between J779 and J785 for an open circuit or a short circuit. The wire between J779 and J785 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P785-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P785-3 (+) and GND (-). Actuate the DADF APS 3 Sensor with paper. The voltage changes. Y↓N→Replace the DADF APS 3 Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 005-918
  • Description: CVT Invert Sensor Static Jam RAP CVT Invert Sensor On detected at the timing below: 1. Power On 2. Feeder Cover Interlock Close 3. Platen Interlock Close.
  • Remedy: If the problem occurs frequently, make sure that there is no obstacle blocking the light path on CVT Invert Sensor. Check the connections between the CVT Invert Sensor and the DADF PWB. If OK, replace the CVT Invert Sensor. If the problem persists, replace the DADF PWB (PL 15.3).
  • Code: 005-919
  • Description: DADF Tray Lift Up Failure RAP The following detected: With the document being set, Level Sensor does not turn On or Bottom Snr does not turn Off in a specified time from start of Tray Lift Up. Detected except for During Run, during Stop, or during Purge.
  • Remedy: Removal of set document cancels the fault. If it occurs frequently, check the Level Sensor, Tray Motor, Tray Drive Assembly, area for binding, damage, and/or debris. Check the connections between the Level Sensor and the DADF PWB. If OK, replace the Level Sensor. If the problem persists, replace the DADF PWB (PL 15.3).
  • Code: 005-942
  • Description: 005-942 Doc fault loading on DADF RAP Due to too many document sheets, no documents could not be fed.
  • Remedy: Manually operate the Feed Head mechanism. The Feed Head mechanism moves smoothly. Y↓N→Replace the parts that are interfering with operation. Execute Component Control[005-225 DADF Nudger Sensor]. Actuate the DADF Nudger Sensor with paper. The display changes. Y↓N→Check the connections of P/J788 and P/J786. P/J788 and P/J786 are connected correctly. Y↓N→Connect P/J788 and P/J786. Check the wire between J788 and J786 for an open circuit or a short circuit. The wire between J788 and J786 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P786-7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P786-9 (+) and GND (-). Actuate the DADF Nudger Sensor with paper. The voltage changes. Y↓N→Replace the DADF Nudger Sensor (PL 15.5). Replace the DADF PWB (PL 15.3). Execute Component Control[005-090]. The DADF Nudger Motor (PL 15.6) can be heard. Y↓N→Check the connections of P/J787 and P/J786. P/J787 and P/J786 are connected correctly. Y↓N→Connect P/J787 and P/J786. Check the wire between J787 and J786 for an open circuit or a short circuit. The wire between J787 and J786 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P786-1 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Nudger Motor (PL 15.6). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).
  • Code: 010-313
  • Description: Control (Center) Thermistor Failure RAP The Control (Center) Thermistor has an open circuit.
  • Remedy: Check the installation of the Fuser Unit. The Fuser Unit is securely installed. Y↓N→Install the Fuser Unit securely. Check the resistance of the Center Thermistor between P600-5 and P600-6. The resistance is 3k ohms or higher. Y↓N→Replace the Fuser Unit (PL 5.1). Check the wire between P/J410 and J600 for an open circuit or a short circuit. The wire between J410 and J600 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Fuser Unit (PL 5.1). If the problem persists, replace the MCU PWB (PL 9.1).
  • Code: 010-314
  • Description: Rear Thermistor Failure RAP
  • Remedy: Check the installation of the Fuser Unit. The Fuser Unit is securely installed. Y↓N→Install the Fuser Unit securely. Check the resistance of the Rear Thermistor between J600-2 and J600-4. The resistance is 3k ohms or higher. Y↓N→Replace the Fuser Unit (PL 5.1). Check the wire between P/J410 and J600 for an open circuit or a short circuit. The wire between J410 and J600 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Fuser Unit (PL 5.1). If the problem persists, replace the MCU PWB (PL 9.1).