Description: Ejector Movement Failure RAP 11-320-110 The ejector is not at the home position. 11-322-110 The ejector fails to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to cycle from the home position to the out position and back to the home position.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. NOTE: In diagnostics, actuating any 2K LCSS sensor or switch can change the displayed state on the UI. Make sure that the correct sensor or switch is tested. Enter dC330, code 11-322, actuate the ejector out sensor, Q11-322. The display changes. Y↓N→Go to Flag 2. Check Q11-322. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J304, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, Q11-322, PL 11.18 Item 3. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330, code 11-320, actuate the ejector home sensor, Q11-320. The display changes. Y↓N→Go to Flag 1. Check Q11-320. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J304, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, Q11-320, PL 11.18 Item 3. • 2K LCSS PWB, PL 11.26 Item 1. Enter dC330, code 11-023 to check the movement of the ejector. The ejector motor runs. Y↓N→Go to Flag 3. Check the ejector motor, MOT11-020. Refer to: • 11G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. •. • P/J303, 2K LCSS PWB. • 11D-110 2K LCSS Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 11.18 Item 1. • 2K LCSS PWB, PL 11.26 Item 1. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 11.20 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 11.18 Item 1. Perform SCP 6 Final Actions. Go to Flag 4. +5v is available at P/J304 between pins 7 and 8. Y↓N→Go to the 11D-110 2K LCSS Power Distribution RAP. Connect a service meter at P/J304 between pins 8 and 9. Slowly rotate the ejector motor encoder. The voltage changes between +5V and 0V. Y↓N→Go to Flag 4. Check the wiring and connectors between the ejector motor encoder sensor and the 2K LCSS PWB. If necessary repair the wiring. If the wiring is good, install a new ejector motor encoder sensor, PL 11.18 Item 3. Perform the 11G-110 2K LCSS PWB Damage RAP, if necessary install a new 2K LCSS PWB, PL 11.26 Item 1.
Description: Ejector Movement Failure RAP 11-320-120 The ejector is not at the home position. 11-322-120 The ejector fails to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to move from the home position to the out position and back to the home position.
Remedy: NOTE: All 1K LCSS interlocks must be made to supply +24V to the motors. NOTE: In diagnostics, actuating any 1K LCSS sensor or switch can change the displayed state on the UI. Make sure that the correct sensor or switch is tested. NOTE: For clarity, the 1K LCSS is shown removed from the machine. Enter dC330, code 11-322, ejector out sensor, Q11-322. Actuate Q11-322. The display changes. Y↓N→Go to Flag 2. Check Q11-322. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J8, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, Q11-322, PL 11.114 Item 3. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330, code 11-320, ejector home sensor, Q11-320. Actuate Q11-320. The display changes. Y↓N→Go to Flag 1. Check Q11-320. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. •. • P/J8, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, Q11-320, PL 11.114 Item 3. • 1K LCSS PWB, PL 11.124 Item 1. Enter dC330, code 11-023 to check the operation of the ejector motor, MOT11-020. MOT11- 020 runs. Y↓N→Go to Flag 3. Check MOT11-020. Refer to: • 11F-120 1K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. •. • P/J15, 1K LCSS PWB • 11C-120 1K LCSS Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 11.114 Item 1. • 1K LCSS PWB, PL 11.124 Item 1. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed, refer to the 11-364-120 Stapling Failure RAP. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 11.116 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 11.114 Item 1. Perform SCP 6 Final Actions. Go to Flag 4. +5V is available at P/J8 between pins 7 and 8. Y↓N→Go to the 11C-120 1K LCSS Power Distribution RAP. Connect a service meter at P/J8 between pins 8 and 9. Slowly rotate the ejector motor encoder. The voltage changes between +5V and 0V. Y↓N→Go to Flag 4. Check the wiring and connectors between the ejector motor encoder sensor and the 1K LCSS PWB. If necessary repair the wiring. If the wiring is good, install a new ejector motor encoder sensor, PL 11.114 Item 3. Perform the 11F-120 1K LCSS PWB Damage RAP, if necessary install a new 1K LCSS PWB, PL 11.124 Item 1.
Description: Compiler Ejector Movement Failure RAP 11-320-130 The compiler ejector is not at the home position. 11-322-130 The compiler ejector fails to complete a cycle of operation. NOTE: The home position for the compiler ejector is with the ejector closed. NOTE: A cycle of operation for the compiler ejector is to cycle between closed to open, then back to closed.
Remedy: Enter dC330, codes 11-023 to run the ejector motor. The ejector opens fully, then closes. Y↓N→Go to Flag 3. Check the ejector motor, MOT 11-020. Refer to: • GP 10, How to Check a Motor. • P/J406, Carriage PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.46 Item 5. • Ejector motor assembly, PL 11.47 Item 2. Enter dC330, code 11-320, actuate the ejector home sensor, Q11-320. The display changes. Y↓N→Go to Flag 1 and Flag 4. Check the sensor. Refer to: • GP 11, How to Check a Sensor. • P/J409 and P/J411, Carriage PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.46 Item 5. • Ejector home sensor, PL 11.47 Item 3. Enter dC330, code 11-317, actuate the compiler carriage safety switch, S11-317. The display changes. Y↓N→Go to Flag 2. Check the compiler carriage safety switch. Refer to: • GP 13 How to Check a Switch. • P/J406, Carriage PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.46 Item 5. • Compiler Carriage safety switch, PL 11.47 Item 4. Go to Flag 5, check the harness and P/J412 and P/J432, refer to GP 7. The wiring and connectors are good. Y↓N→Repair the wiring or install new components. Perform SCP 6 Final Actions.
Description: Compiler Ejector Movement Failure RAP 11-320-170 The compiler ejector is not at the home position. 11-322-170 The compiler ejector fails to complete a cycle of operation. NOTE: The home position for the compiler ejector is with the ejector closed. NOTE: A cycle of operation for the compiler ejector is to move between closed to open, then back to closed.
Remedy: Enter dC330, code 11-023 to run the eject motor, MOT11020. The ejector opens fully and then closes. Y↓N→Go to Flag 3. Check the ejector motor, MOT 11-020. Refer to: • GP 10, How to Check a Motor. • P/J406, Carriage PWB. • 11C-170 HCSS BM Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.72 Item 5. • Ejector motor assembly, PL 11.73 Item 2. Enter dC330, code 11-320, actuate the ejector home sensor, Q11-320. The display changes. Y↓N→Go to Flag 1 and Flag 4. Check the sensor, Q11-320. Refer to: • GP 11, How to Check a Sensor. • P/J409 and P/J411, Carriage PWB. • 11C-170 HCSS BM Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.72 Item 5. • Ejector home sensor, PL 11.73 Item 3. Enter dC330, code 11-317, actuate the compiler carriage safety switch, S11-317. The display changes. Y↓N→Go to Flag 2. Check the switch, S11-317. Refer to: • GP 13, How to Check a Switch. • P/J406, Carriage PWB. • 11C-170 HCSS BM Power Distribution RAP. Install new components as necessary: • Carriage PWB, PL 11.72 Item 5. • Compiler carriage safety switch, PL 11.73 Item 4. Go to Flag 5, check the connectors and harness between P/J412 and P/J432, refer to GP 7. The harness and connectors are good. Y↓N→Repair the harness, or install new components. Perform SCP 6 Final Actions.
Description: Bin 1 Elevate Failure RAP 11-334-130 The bin 1 upper limit switch has been made. 11-335-130 The bin 1 lower limit switch has been made. 11-336-130 Bin 1 fails to move to the home position.
Remedy: Enter dC330, codes 11-030, 11-031, 11-032 and 11-033 to run the bin 1 elevator motor, MOT 11-030. Check the movement of bin 1. Bin 1 moves correctly. Y↓N→Go to Flag 3. Check the bin 1 elevator motor, MOT 11-030. Refer to: • GP 10, How to Check a Motor. • P/J424, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 1 elevator motor, PL 11.52 Item 11. • HCSS PWB, PL 11.56 Item 5. Enter dC330, code 11-334, actuate the bin 1 upper limit switch, S11-334. The display changes. Y↓N→Go to Flag 2. Check the switch S11-334. Refer to: • GP 13, How to Check a Switch. • P/J424, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 1 upper limit switch, PL 11.52 Item 1. • HCSS PWB, PL 11.56 Item 5. Enter dC330, code 11-335, actuate the bin 1 lower limit switch, S11-335. The display changes. Y↓N→Go to Flag 1. Check the switch S11-335. Refer to: • GP 13, How to Check a Switch. • P/J424, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 1 lower limit switch, PL 11.52 Item 2. • HCSS PWB, PL 11.56 Item 5. Perform SCP 6 Final Actions.
Description: Bin 1 Elevate Failure RAP 11-334-170 The bin 1 upper limit switch has been actuated. 11-335-170 The bin 1 lower limit switch has been actuated. 11-336-170 Bin 1 fails to move to the home position.
Remedy: Enter dC330, codes 11-030, 11-031, 11-032 and 11-033, to check the movement of bin 1. Bin 1 moves correctly. Y↓N→Go to Flag 3. Check the bin 1 elevator motor, MOT 11-030. Refer to: • GP 10, How to Check a Motor. • P/J424, HCSS PWB. • 11C-170 HCSS BM Power Distribution RAP. Install new components as necessary: • Bin 1 elevator motor, PL 11.78 Item 11. • HCSS PWB, PL 11.92 Item 5. Enter dC330, code 11-334, actuate the bin 1 upper limit switch, S11-334. The display changes. Y↓N→Go to Flag 2. Check the switch S11-334. Refer to: • GP 13, How to Check a Switch. • P/J424, HCSS PWB. • 11C-170 HCSS BM Power Distribution RAP. Install new components as necessary: • Bin 1 upper limit switch, PL 11.78 Item 1. • HCSS PWB, PL 11.92 Item 5. Enter dC330, code 11-335, actuate the top bin 1 lower limit switch, S11-335. The display changes. Y↓N→Go to Flag 1. Check the switch S11-335. Refer to: • GP 13, How to Check a Switch. • P/J424, HCSS PWB. • 11C-171 HCSS BM Power Distribution RAP.
Description: Bin 2 Elevate Failure RAP 11-344-130 The bin 2 upper limit switch has been made. 11-345-130 The bin 2 lower limit switch has been made. 11-346-130 Bin 2 fails to move to the home position.
Remedy: Enter dC330, codes 11-036, 11-037, 11-038 and 11-039 to run the bin 2 elevator motor, MOT 11-030. Check the movement of bin 2. Bin 2 moves correctly. Y↓N→Go to Flag 3. Check the bin 2 elevator motor, MOT11-030. Refer to: • GP 10, How to Check a Motor. • P/J431, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 2 elevator motor, PL 11.54 Item 11. • HCSS PWB, PL 11.56 Item 5. Enter dC330, code 11-344. Actuate the bin 2 upper limit switch, S11-344. The display changes. Y↓N→Go to Flag 2. Check the switch, S11-344. Refer to: • GP 13 How to Check a Switch. • P/J431, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 2 upper limit switch, PL 11.54 Item 1. • HCSS PWB, PL 11.56 Item 5. Enter dC330, code 11-345. Actuate the bin 2 lower limit switch, S11-345. The display changes. Y↓N→Go to Flag 1. Check the switch, S11-345. Refer to: • GP 13 How to Check a Switch. • P/J431, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Bin 2 lower limit switch, PL 11.54 Item 2. • HCSS PWB, PL 11.56 Item 5. Perform SCP 6 Final Actions
Description: Hole Punch Not Home RAP 11-350-130 The hole punch is not at the home position. NOTE: The home position of the punch unit is when the cutout in the actuator is between the punch head home sensor jaws.
Remedy: Enter dC330, codes 11-043 punch head run, then 11-042 punch head move home.. The punch cycles then goes to the home position Y↓N→Go to Flag 2. Check the hole punch motor, MOT11-042. Refer to: • GP 10, How to Check a Motor. • PJ421, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Hole punch motor, PL 11.38 Item 7. • HCSS PWB, PL 11.56 Item 5. Enter dC330, code 11-350 actuate the hole punch home sensor, Q11-350. The display changes. Y↓N→Go to Flag 1. Check the sensor, Q11-350. Refer to: • GP 11, How to Check a Sensor. • PJ420, HCSS PWB. • 11C-130 HCSS Power Distribution RAP. Install new components as necessary: • Hole punch home sensor, PL 11.38 Item 8. • HCSS PWB, PL 11.56 Item 5. Perform SCP 6 Final Actions.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.