Causes: An error in current of the IH Power Supply PCB was detected. (ASIC detection)
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the IH Power Supply PCB (UN30/J510), the Drawer Unit (J8027) and the Main Heater (H4) - Fixing Film Unit - Main Heater (H4) - IH Power Supply PCB (UN30) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: An error in current of the IH Power Supply PCB was detected. (Software detection)
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the IH Power Supply PCB (UN30/J510), the Drawer Unit (J8027) and the Main Heater (H4) - Fixing Film Unit - Main Heater (H4) - IH Power Supply PCB (UN30) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: An error in the IH Power Supply Unit (12 V line) was detected.
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the Pickup Driver PCB (UN4/J1492), the Drawer Unit (J8001) and the IH Thermoswitch (TP2/J8025) - Harness between the Pickup Driver PCB (UN4/J1480) and the Relay PCB (UN7/J1821) - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Fixing Film Unit - Relay PCB (UN7) - Pickup Driver PCB (UN4) - IH Power Supply PCB (UN30) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: A connection error between the Fixing Film Unit Main Thermistor and the Fixing Film Unit Thermistor (Front) was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: A connection error between the Fixing Film Unit Sub Thermistor 1/2 and the Fixing Film Unit Thermistor (Rear) was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: Feeding of paper equivalent to 60000 counts was detected since the Fixing Web absence notice was generated.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Web Level Sensor (PS102/J8034) - Fixing Web Level Sensor (PS102) - Fixing Web - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the counter value: OPIER> COUNTER> MISC> FX-WEB. a. If the remaining level of the Fixing Web is low, replace the web. b. If the remaining level of the Fixing Web is high, check/replace the related harness/cable, connector and parts.
Description: Connection error of the Fixing Feed Drawer Connector
Causes: An error of the Fixing Feed Unit Switch in the Drawer Unit was detected.
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1480) and the Fixing Feed Unit Switch (SW7/ J8057) - Harness between the Side Driver PCB (UN96/J1306) and the Front Cover Open/Close Sensor (PS80/J8094) - Harness between the Relay PCB (UN7/J1821) and the Pickup Driver PCB (UN4/J1480) - Fixing Feed Unit Switch (SW7) - Front Cover Open/Close Sensor (PS80) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.
Description: Connection error of the Fixing Feed Drawer Connector
Causes: An error of the connector in the Drawer Unit was detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN2/J1222), the Drawer Unit (J8023) and the Fixing Feed Driver PCB (UN5/J1510) - Harness between the Pickup Driver PCB (UN4/J1480) and the Fixing Feed Unit Switch (SW7/ J8057) - Harness between the Side Driver PCB (UN96/J1306) and the Front Cover Open/Close Sensor (PS80/J8094) - Harness between the Relay PCB (UN7/J1821) and the Pickup Driver PCB (UN4/J1480) - Front Cover Open/Close Sensor (PS80) - Fixing Feed Unit Switch (SW7) - Pickup Driver PCB (UN4) - Relay PCB (UN7) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.