Description: Insufficient fixing belt temperature rise 4. In a warm-up, the temperature of fixing main thermistor (THM1-1) does not reach to 150 degrees Celsius within 120 seconds after reaching to 130 degrees Celsius.
Remedy: 1. Check the detection temperature of the thermistor in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing belt unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
Code: E002-0006
Description: Insufficient fixing belt temperature rise 5. In a warm-up, the temperature of fixing main thermistor (THM1-1)does not reach to the specified temerature for temperature control after reaching to 150 degrees Celsius.
Remedy: 1. Check the detection temperature of the thermistor in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing belt unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
Code: E002-0102
Description: Insufficient pressure belt temperature rise 1. In a warm-up, the temperature of pressure main thermistor (THM2) does not reach to 80 degrees Celsius within 250 seconds after reaching to 50 degrees Celsius.
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure belt main thermistor (to see if the thermistor is disconnected, the harness of the thermistor is disconnected, foreign substance is in the thermistor, failure of the thermistor) -> replace the pressure main thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly
Code: E003-0001
Description: Fixing belt abnormally low temperature. After standby, fixing main thermistor (THM1-1) detected less or equal to 130 degrees Celsius in succession for ten seconds.
Remedy: 1. Check the rear louver. (If the rear of the machine is close to the wall, temperature of the power supply area may rise) 2. Check the detection temperature of the thermistor in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing belt unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
Code: E003-0002
Description: Pressure belt abnormally low temperature. After standby, pressure main thermistor (THM2) detected less or equal to 50 degrees Celsius in succession for ten seconds.
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure main thermistor (to see if the thermistor is disconnected, the harness of the thermistor is disconnected, foreign substance is in the thermistor, failure of the thermistor) -> replace the pressure main thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly
Code: E003-0003
Description: Perssure belt abnormally low temperature. After went in standby, Pressure sub thermistor 1(THM3) detected less or equal to 50 degrees Celsius for specified time (250sec)
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure sub thermistor 2 (to see if the location of the thermistor is inappropriate, the harness of the thermistor is disconnected, failure of the thermistor) -> replace the pressure sub thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly
Code: E003-0004
Description: Perssure belt abnormally low temperature. After went in standby, Pressure sub thermistor 2(THM4) detected less or equal to 50 degrees Celsius for specified time (250sec)
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure sub thermistor 2 (to see if the location of the thermistor is inappropriate, the harness of the thermistor is disconnected, failure of the thermistor) -> replace the pressure sub thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly
Code: E004-0101
Description: Triac short error. Triac short in Halogen heater was detected (ASIC detection)
Remedy: 1. Check the connection of the halogen heater (to see if the cable is disconnected or the connector is physically removed) -> connect the connector or replace the heater 2. Faulty halogen heater (to see if there is crack or the connector is disconnected) -> replace the heater 3. Check the pressure thermoswitch (TP2) (to see if it is disconnected) -> replace teh pressure stay or the fixing assembly 4. AC driver PCB replacement 5. DC controller board replacement