Code :
  • Code: E007-0011
  • Description: Fixing belt displacement failure (front side)It was detected that the fixing belt was displaced to the position of Front 2 (front side at 3mm from the center).
  • Remedy: 1. Forgot to clear the counter at the fixing belt replacement -> clear the counter 2. Check physical relationship between the fixing belt position sensor 1, 2 (PS71, 72) and the sensor flag A. In case that both sensors are blocked from light A-1. Faulty fixing belt unit -> replace the fixing belt unit A-2. Faulty fixing belt displacement control drive -> replace the displacement control drive assembly B. In case that both sensors are not blocked from light B-1. The connector on the fixing belt position sensor 1, 2 (PS71, 72) is physically removed, or the cable is disconnected -> connect the connector, or replace the harness B-2. Faulty fixing belt position sensor 1, 2 (PS71, 72) -> replace the sensor B-3. Faulty fixing belt unit -> replace the fixing belt unit B-4. Faulty fixing feed driver PCB -> replace teh fixing feed driver PCB
  • Code: E007-0012
  • Description: Pressure belt displacement failure (front side). It was detected that the pressure belt did not return to the center from the position of Front 1 (front side at 1mm from the center) even after a specified period
  • Remedy: 1. Check installation of the pressure belt displacement control drive -> correct to the right installation procedure 2. Faulty pressure belt unit -> replace the pressure belt unit 3. Faulty pressure belt position sensor 1, 2 (PS76, 77) or faulty position sensor flag -> replace the pressure stay 4. Faulty drawer connector -> clean the drawer connector or replace the fixing unit 5. Faulty fixing feed driver PCB -> replace the fixing feed driver PCB
  • Code: E007-0021
  • Description: Fixing belt displacement failure (rear side). It was detected that the fixing belt was displaced to the position of Rear 2 (rear side at 3mm from the center).
  • Remedy: 1. Forgot to clear the counter at the fixing belt replacement -> clear the counter 2. Check physical relationship between the fixing belt position sensor 1, 2 (PS71, 72) and the sensor flag A. In case that both sensors are blocked from light A-1. Faulty fixing belt unit -> replace the fixing belt unit A-2. Faulty fixing belt displacement control drive -> replace the displacement control drive assembly B. In case that both sensors are not blocked from light B-1. The connector on the fixing belt position sensor 1, 2 (PS71, 72) is physically removed, or the cable is disconnected -> connect the connector, or replace the harness B-2. Faulty fixing belt position sensor 1, 2 (PS71, 72) -> replace the sensor B-3. Faulty fixing belt unit -> replace the fixing belt unit B-4. Faulty fixing feed driver PCB -> replace teh fixing feed driver PCB
  • Code: E007-0022
  • Description: Pressure belt displacement failure (rear side). It was detected that the pressure belt did not return to the center from the position of Rear 1 (rear side at 1mm from the center) even after a specified period.
  • Remedy: 1. Check installation of the pressure belt displacement control drive -> correct to the right installation procedure 2. Faulty pressure belt unit -> replace the pressure belt unit 3. Faulty pressure belt position sensor 1, 2 (PS76, 77) or faulty position sensor flag -> replace the pressure stay 4. Faulty drawer connector -> clean the drawer connector or replace the fixing unit 5. Faulty fixing feed driver PCB -> replace the fixing feed driver PCB
  • Code: E007-0101
  • Description: Fixing belt home position detection error. Fixing belt home position detection error (Failure of the fixing belt HP sensor (PS69))
  • Remedy: 1. Check installation of the fixing belt displacement control drive -> correct to the right installation procedure 2. Check if there is open circuit of the harness between the fixing belt displacement control drive unit and the fixing feed driver PCB, or the connector is physically removed -> if it is open circuit, replace the harness 3. Faulty fixing belt HP sensor flag -> if the behavior is not normal, replace it 4. Replace the fixing belt HP sensor (PS69) 5. Replace the fixing belt displacement control motor (M46) 6. Replace the fixing feed driver PCB 7. Replace the DC controller PCB
  • Code: E007-0102
  • Description: Pressure belt home position detection error. Pressure belt home position detection error (Failure of the pressure belt HP sensor (PS78))
  • Remedy: 1. Check installation of the pressure belt displacement control drive -> correct to the right installation procedure 2. Check if there is open circuit of the harness between the pressure belt displacement control drive unit and the fixing feed driver PCB, or the connector is physically removed -> if it is open circuit, replace 3. Faulty pressure belt HP sensor flag -> if the behavior is not normal, replace it 4. Replace the pressure belt HP sensor (PS78) 5. Replace the pressure belt displacement control motor (M49) 6. Replace the fixing feed driver PCB 7. Replace the DC controller PCB
  • Code: E007-9901
  • Description: Fixing belt displacement failure (Full displacement of the fixing belt or failure of the fixing belt position sensor). Failure of the fixing belt position sensor (An impossible combination of sensor signals occurred.)
  • Remedy: 1.Check if there is open circuit of the harness between the fixing belt position sensor 1, 2 (PS71, 72) and the fixing feed driver PCB, or the connector is physically removed -> if it is open circuit, replace 2. Check if the installation of the fixing belt position sensor 1, 2 (PS71, 72) is inappropriate 3. Faulty fixing belt position sensor 1, 2 (PS71, 72) -> replace the sensor 4. Faulty fixing belt unit -> replace the fixing belt unit
  • Code: E007-9902
  • Description: Pressure belt displacement failure (Full displacement of the pressure belt or failure of the pressure belt position sensor). Failure of the pressure belt position sensor (An impossible combination of sensor signals occurred.)
  • Remedy: 1. Faulty connection of the drawer connector -> clean the drawer connector 2. Faulty pressure belt position sensor 1, 2 (PS76, 77), open circuit of the harness, or the connector is physically removed -> connect the connector, replace the sensor or replace teh pressure stay 3. Faulty drawer connector -> replace the fixing unit