Description: Thermistor temperature difference error. Difference of detected temperature between thermistors is bigger than the specified value
Remedy: 1. The connectors of the fixing main/sub thermistor (THM1-1 to 3) are physically removed (the cable is caught, or disconnected) -> replace the fixing belt unit 2. Check the rotation of the fixing motor (the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. The connectors of the pressure sub thermistor (THM2,3,4) are physically removed (the cable is caught, or disconnected) -> replace the thermistor or the presure stay 4. Disconnection, soiled, improper location of, or faulty pressure sub thermistor (THM2,3,4) -> clean the thermistor or replace it 5. Faulty drawer connector -> clean the drawer connector or replace the fixing unit 6. Replace the DC controller PCB
Description: Relay off state error (circuit failure). Detected that the relay is OFF.
Remedy: 1. Check the fixing belt -> if it is damaged, replace the fixing belt unit 2. Check the connection of the fixing fuse PCB -> replace the fuse PCB 3. Check the connection of the fixing thermoswitch (TP2) (thermoswitch is OFF, or the cable is disconnected) -> replace the fixing belt unit 4. Relay PCB replacement 5. DC controller replacement 6. IH power supply replacement
Description: Fixing belt full displacement error (Displacement direction is unknown.). Full displacement of the fixing belt was detected, but the displacement direction (front, rear) was unknown.
Remedy: 1. Forgot to clear the counter at the fixing belt replacement -> clear the counter 2. Check physical relationship between the fixing belt position sensor 1, 2 (PS71, 72) and the sensor flag A. In case that both sensors are blocked from light A-1. Faulty fixing belt unit -> replace the fixing belt unit A-2. Faulty fixing belt displacement control drive -> replace the displacement control drive assembly B. In case that both sensors are not blocked from light B-1. The connector on the fixing belt position sensor 1, 2 (PS71, 72) is physically removed, or the cable is disconnected -> connect the connector, or replace the harness B-2. Faulty fixing belt position sensor 1, 2 (PS71, 72) -> replace the sensor B-3. Faulty fixing belt unit -> replace the fixing belt unit B-4. Faulty fixing feed driver PCB -> replace teh fixing feed driver PCB
Description: Pressure belt full displacement error (Displacement direction is unknown.). Full displacement of the pressure belt was detected, but the displacement direction (front, rear) was unknown.
Remedy: 1. Check installation of the pressure belt displacement control drive -> correct to the right installation procedure 2. Faulty pressure belt unit -> replace the pressure belt unit 3. Faulty pressure belt position sensor 1, 2 (PS76, 77) or faulty position sensor flag -> replace the pressure stay 4. Faulty drawer connector -> clean the drawer connector or replace the fixing unit 5. Faulty fixing feed driver PCB -> replace the fixing feed driver PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.