Code: E584-01

Description: • Feed motor (M1) • Shutter closed detecting switch (MS4)
• The shutter closed detecting switch does not turn on when the feed motor is rotated in reverse for 1 sec or more.
Remedy:

Code: E584-02

Description: • Feed motor switch (M1) • Shutter closed detecting switch (MS4)
• The shutter open sensor does not turn on when the feed motor is rotated in reverse for 1 sec or more.
Remedy:

Code: E584-03

Description: • Safety area detecting switch (MS3) • Shutter closed detecting switch (MS4)
• The shutter closed detecting switch is found to be off when the tray 1/2 is in the safety area switch OFF position.
Remedy:

Code: E606

Description: The HDD is faulty.
• The HDD cannot be recognized normally at power-on. • An error occurs while writing to or reading from the HDD.B?
Remedy: Connector (poor contact) 1) Are connectors J701 and J702 of the HDD and connectors J306 and J307 of the relay PCB connected securely? NO: Connect the connectors securely. Relay PCB 2) Is connector J301 of the relay PCB and J1017 of the system controller PCB connected securely? NO: Connect them securely. HDD, System controller PCB 3) Try replacing the HDD. Is the problem corrected? YES: End. NO: Replace the system controller PCB.

Code: E676

Description: The PDL PCB has a communication error.
• The communication with the PDL PCB fails in initialization sequence. • The registration of the PDL-unique menu fails. • While PDL is in operation, a check sum error of the received packet is detected. • While PDL is in operation, a format error in the received packet is detected. • There is no response in the course of a check on the PDL board operation.
Remedy: Connector (poor contact) 1) Is the PDL PCB securely connected to J303 of the relay PCB? NO: Connect it securely. Relay PCB 2) Are connector J301 of the relay PCB and connector J1017 of the system controller PCB connected securely? NO: Connect the connectors securely. PDL PCB, System controller PCB 3) Try replacing the PDL PCB. Is the problem corrected? YES: End. NO: Replace the system controller PCB.

Code: E677

Description: The PDL PCB is faulty.
• An error occurs on the PDL board.
Remedy: Connector (poor contact) 1) Is the PDL PCB securely connected to J303 of the relay PCB? NO: Connect it securely. Relay PCB 2) Are connector J301 of the relay PCB and connector J1017 of the system controller PCB connected securely? NO: Connect the connectors securely. PDL PCB, System controller PCB 3) Try replacing the PDL PCB. Is the problem corrected? YES: End. NO: Replace the system controller PCB.

Code: E710

Description: The initialization of the IPC fails.
• At power-on or during sleep return, initialization communication with the finisher fails.
Remedy: 1) Turn off and then on the power. Is the problem corrected? YES: End. If the problem occurs frequently, check the communication cable to the finisher. Connector (poor contact) 2) Is the connection between the machine and the finisher secure? NO: Make the connection secure. Communication cable 3) Try replacing the communication cable to the finisher. Is the problem corrected? YES: End. Finisher controller PCB, System controller PCB 4) Try replacing the finisher controller PCB of the finisher. Is the problem corrected? YES: End. NO: Replace the system controller PCB.

Code: E711

Description: An IPC register error occurs.
• An error occurs frequently in the communication between the finisher and the machine.
Remedy: 1) Turn off and then on the power. Is the problem corrected? YES: End. If the problem occurs frequently, check the communication cable to the finisher. Connector (poor contact) 2) Is the connection between the machine and the finisher secure? NO: Make the connection secure. Communication cable 3) Try replacing the communication cable to the finisher. Is the problem corrected? YES: End. Finisher controller PCB, System controller PCB 4) Try replacing the finisher controller PCB of the finisher. Is the problem corrected? YES: End. NO: Replace the system controller PCB.