Description: The heater fails to heat. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
After power-on, the reading of the main thermistor does not increase to 70 deg C or higher within 20 sec.
Remedy: - Replace the main/shutter thermistor. - Replace the DC controller PCB.
Code: E000-0010
Description: The heater fails to heat. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E001-0001
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is an error or an open circuit in the main thermistor, shutter thermistor, or sub thermistor.
Remedy: - Check the connector of each thermistor for any fault in connection and wiring. - Replace the thermistor in question. - Replace the DC controller PCB.
Code: E001-0002
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor, shutter thermistor, or sub thermistor is 230 deg C or higher for 2 sec.
Remedy: - Replace the thermistor in question. - Replace the DC controller PCB.
Code: E001-0003
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading is not 150 deg C or higher or 210 deg C or lower within 30 sec.
Remedy: -Cheak the connecting of the main/ sub/ shutter thermistors. -Check the mounting of the main/ sub/ shutter thermistors. -Exchange the main/ sub/ shutter thermistors. -Exchange the DC controller PCB.
Code: E001-0010
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E002-0000
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is not 100 deg C 12 sec after it has exceeded 70 deg C.
Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
Code: E002-0001
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is not 150 deg C 15 sec after it has exceeded 100 deg C.
Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.