Các lỗi thường gặp

Code :
  • Code: E000
  • Description: The temperature of the upper fixing roller has not increased above the specified level 90 seconds after switching power on. The temperature of the upper fixing roller does not reach 150 C within 8 minutes after switching power ON. The temperature of the upper fixing roller does not reach 180 C within 5 minutes of reaching 150 C. The temperature of the upper fixing roller drops below 50 C during STANDBY.
  • Code: E001
  • Description: The temperature of the upper fixing roller exceeds 250 C.
  • Code: E005
  • Description: The length of fixing assembly cleaning belt wound on the take-up reel exceeds the specified length.
  • Code: E010
  • Description: When two or more clock pulses are not inputted for a period of 2 seconds after a MAIN MOTOR DRIVE command is generated.
  • Code: E011
  • Description: When excessive current is detected by the fault detection circuit of the DC driver PCB. When excessive current is detected by the fault detection circuit of the duplexing unit driver PCB. When excessive current is detected by the fault detection circuit of the scanner motor driver PCB.
  • Code: E020
  • Description: When a toner out signal (TSP) is emitted from the developing assembly for a total of at least two minutes.
  • Code: E050
  • Description: When the HOLDING TRAY HOME POSITION signal (THP) is not generated within 4 seconds from the beginning of HOLDING TRAY MOTOR DRIVE command (TMDP1,2) When the HOLDING TRAY HOME POSITION signal (THP) is generated for at least one second while the HOLDING TRAY MOTOR DRIVE command (TMDSP1,2) is being generated.
  • Code: E203
  • Description: When two or more clock pulses are not inputted from the SCANNER MOTOR DRIVE command is being generated.