Code :
  • Code: E113
  • Description: Laser malfunction (Black)
    - SOS signal is not detected within the lapse of a given period of time after staring the laser output.
    - SOS signal is not detected within a given period of time during printing or IDC sensor adjustment
  • Causes: • PH Unit • PH Interface Board (PWB-D) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the connector for proper connection and correct as necessary. - - 2 Change PH Unit - - 3 Change PWB-D - - 4 Change PWB-M
  • Code: E200
  • Description: Transfer Belt Separation
    - The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting.
    - The 1st Image Transfer Pressure/Retraction Position Sensor doesn't turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring.
  • Causes: • 1st Image Transfer Pressure/Retraction Position Sensor (PC6) • 1st Image Transfer Pressure/Retraction Clutch (CL3) • Main Motor (M1) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 PC6 I/O check, Sensor check - - 3 CL3 operation check PWB-M CNDM1-11 (ON) K to L-2 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2 5 Change PWB-M
  • Code: E210
  • Description: 2nd Transfer Roller Separation
    - The 2nd Image Transfer Pressure Position Sensor doesn't turn ON (Retracting) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Transfer Roller is retracting.
    - The 2nd Image Transfer Pressure Position Sensor doesn't turn OFF (Pressuring) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Transfer Roller is pressuring.
  • Causes: • Mechanical Control Board (PWB-M) • Right Door
  • Remedy: 1 Check the connector of motor for proper connection and correct as necessary. - - 2 Change Right Door - - 3 Change PWB-M
  • Code: E220
  • Description: Transfer Belt Unit New Article Release
    - A new installation is not detected when a new Transfer Belt Unit is installed.
  • Causes: Mechanical Control Board (PWB-M)
  • Remedy: 1 Reinstall the Unit. - - 2 Change PWB-M
  • Code: E300
  • Description: Abnormally low Heating Roller temperature
    - The temperature of the Heating Roller Thermistor/1 (TH1) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing.
    - The temperature of the Heating Roller Thermistor/2 (TH3) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing.
  • Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1
  • Code: E301
  • Description: Abnormally low Fusing Pressure Roller temperature
    - The temperature of the Fusing Pressure Roller Thermistor /1 (TH2) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing
  • Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1
  • Code: E302
  • Description: Abnormally high Heating Roller temperature
    - The temperatures of the Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) are higher than a given level of degree for 1 second or more uninterruptedly.
    - The Heater Relay is OFF.
  • Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1
  • Code: E303
  • Description: Abnormally high Fusing Pressure Roller temperature
    - The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts.
    - The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
  • Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1