Description: Heating Roller warm-up failure - The Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) fails to raise a given degree of temperature even after the lapse of a given period of time after the Heating Roller Heater lamp/1 (H1) is turned ON. - The detected temperature of the Heating Roller Thermistor/1 (TH1) is lower for a given level of degree than one of the Fusing Pressure Roller Thermistor/1 (TH2) after the Front Cover is opened or closed, the Main Power Switch is turned ON, or TROUBLE RESET is implemented. - The counter value of zero cross signal input is not updated for a given period of time.
Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1
Description: Fusing Pressure Roller warm-up failure - The Fusing Pressure Roller Thermistor/1 (TH2) fails to raise a given degree of temperature even after the lapse of a given period of time after the Fusing Pressure Heater Lamp (H3) is turned ON. - The detected temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is lower for a given level of degree than one of the Heating Roller Thermistor/1 (TH1) after the Front Cover is opened or closed, the Main Power Switch is turned ON, or TROUBLE RESET is implemented.
Causes: • Fusing Unit • DC Power Supply (PU1) • Mechanical Control Board (PWB-M)
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. - - 3 Change Fusing Unit - - 4 Change PWB-M - - 5 Change PU1
Description: Fusing Unit New Article Release - A new installation is not detected when a new Fusing Unit is installed.
Causes: • Fusing Unit • Mechanical Control Board (PWB-M)
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). - - 2 Check the Fusing Unit, PWB-M for proper connection and correct or change as necessary. - - 3 Reinstall Fusing Unit - - 4 Change Fusing Unit - - 5 Change PWB-M
Description: Abnormally low toner density detected Cyan TCR Sensor - Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 3 M6, M7 operation check PWB-M CNDM2-10 to 13(M6) PWB-M CNDM3-10 to 13(M7) C-22 C-23 4 Reinstall Photoconductor Unit. - - 5 Change Photoconductor Unit. - - 6 Change PWB-M - - 7 Change PWB-P
Description: Abnormally high toner density detected Cyan TCR Sensor - Mixture ratio of the toner and carrier in the developing machine is higher than the specified value.
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 2 Reinstall Photoconductor Unit. - - 3 Change Photoconductor Unit. - - 4 Change PWB-M - - 5 Change PWB-P
Description: Abnormally low toner density detected Magenta TCR Sensor - Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 3 M6, M7 operation check PWB-M CNDM2-10 to 13(M6) PWB-M CNDM3-10 to 13(M7) C-22 C-23 4 Reinstall Photoconductor Unit. - - 5 Change Photoconductor Unit. - - 6 Change PWB-M - - 7 Change PWB-P
Description: Abnormally high toner density detected Magenta TCR Sensor - Mixture ratio of the toner and carrier in the developing machine is higher than the specified value.
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 2 Reinstall Photoconductor Unit. - - 3 Change Photoconductor Unit. - - 4 Change PWB-M - - 5 Change PWB-P
Description: Abnormally low toner density detected Yellow TCR Sensor - Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty. - - 3 M6, M7 operation check PWB-M CNDM2-10 to 13(M6) PWB-M CNDM3-10 to 13(M7) C-22 C-23 4 Reinstall Photoconductor Unit. - - 5 Change Photoconductor Unit. - - 6 Change PWB-M - - 7 Change PWB-P
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.