Description: CR Motor in-position time-out
At Carriage Unit stop processing in CR Motor control, there may be a case where the Carriage Unit can not move to the final target position within a specified period of time (as per pulse detection). In such a case, this message is displayed and the printer stops operating.
Causes: There are pulses smaller than out-of-step pulse remaining without completing paper feed.
Remedy: 1. Check to see if the CR Scale for detection of the encoder pulse is removed. 2. Check for dirt, paper dust or damage to the CR Scale. 3. Perform the CR Timing Belt Tension Adjustment 4. Replace the CR Encoder Sensor 5. Replace the CR_HP Sensor 6. Replace the Motor Assy., CR 7. Replace the C593 MAIN Board
Code: 00010008
Description: Servo interrupt watchdog time-out
During the CR Motor or PF Motor operation, there may be a case where watch dog time-out is detected in the DC motor control circuit or on the ASIC. In such a case, this message is displayed and the printer stops operating.
Causes:
Remedy: Since the cause is deemed to be a defective CPU or ASIC, replace the C593 MAIN Board .
Code: 00010009
Description: System interrupt watchdog time-out
In the data processing stage on the C511 MAIN Board, there may be a case where runaway or defective cash occurs on CPU or ASIC. In such a case, this message is displayed and the printer stops operating.
Causes:
Remedy: If not cleared by turning the power OFF and back ON, the CPU or ASIC is deemed defective, so replace the C593 MAIN Board .
Code: 0001000A
Description: CR axis detection error
During initial operation at power on or during printing operation, there may be a case where the home position can not be detected at the home position detection timing or within a specified period of time. In such a case, this message is displayed and the printer stops operating.
Causes:
Remedy: 1. Check for dirt, paper dust or damage to the CR_HP Sensor. 2. Replace the CR_HP Sensor 3. Replace the C593 MAIN Board
Code: 0001000C
Description: PG axis detection error
During initial operation at power on or during platen gap fluctuation (change) operation after paper setting, there may be a case where the PG home position can not be detected. In such a case, this message is displayed and the printer stops operating.
Causes: • Disconnected connector for the PG Phase Sensor. • Disconnected connector for the PG Motor. • Broken wire for the PG Motor. • Defective PG Phase Sensor. • Defective PG Motor. • Damage to wheel linkage of PG drive gears • Power supply fuse for PG/PO Motor driver is broken on the MAIN Board.
Remedy: 1. Connect PG Phase Sensor or PG Motor connector correctly. 2. Replace the PG Phase Sensor 3. Replace the Motor Assy., PG 4. Replace the C593 MAIN Board
Code: 0001000F
Description: CR Motor PWM output faulty
There may be a case where a current exceeding the specified value flows during CR Motor operation. In such a case, this message is displayed and the printer stops operating. This error can be displayed in the following case: an abnormal load which does not reach the level causing an out-of-step phenomenon "00010005" in the carriage drive system has occurred and the running speed of the motor has been detected to be too low (by the encoder), so that the current is increased to raise the running speed of the motor. Thus, this message appears to prevent the CR Motor from being overheated.
Causes:
Remedy: 1. Check the load on the CR Motor. • Running load of CR Motor (check by manual operation) • Measure the resistance value of the CR Motor. (19.3 ± 10% [Ohm]) • Damage to or wear in the CR Driven Pulley • Damaged or worn bearing of the Carriage Unit • Flaws in the CR Rail caused by roller running • Tension of the CR timing belt 2. Replace the Motor Assy., CR If the CR Motor is found in short mode, replace the C593 MAIN Board at the same time. 3. Replace the C593 MAIN Board unnin
Code: 00010010
Description: PF Motor PWM output faulty
There may be a case where a current exceeding the specified value flows during PF Motor operation. In such a case, this message is displayed and the printer stops operating. This error can be displayed in the following case: an abnormal load which does not reach the level causing an out-of-step phenomenon "00010001" in the paper feed drive system has occurred and the running speed of the motor has been detected to be too low (by the encoder), so that the current is increased to raise the running speed of the motor. Thus, this message appears to prevent the PF Motor from being overheated.
Causes:
Remedy: 1. Check the load on the PF Motor. • Measure the resistance value of the PF Motor. (17.9 ± 15% [Ohm]) If the PF Motor is found in short mode, replace the C593 MAIN Board at the same time. • Running load of PF Motor (check by manual operation) • Rotation load of PF Roller 2. Replace the Motor Assy., PF 3. Replace the C593 MAIN Board
Code: 00010012
Description: CR overload (high sensitivity) error
PWM has been being output for a certain period of time. This can be made when load on the CR Motor is slightly increased.
Causes:
Remedy: 1. Check the load on the CR Motor. • Running load of CR Motor (check by manual operation) • Measure the resistance value of the PF Motor. If the CR Motor is found in short mode, replace the C593 MAIN Board at the same time. • Damage to or wear in the CR Driven Pulley • Damaged or worn bearing of the Carriage Unit • Flaws in the CR Rail caused by roller running • Tension of the CR timing belt 2. Replace the Motor Assy., CR 3. Replace the C593 MAIN Board