Description: APG Motor over speed error
The APG Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • APG encoder failure • APG Motor driver failure
Remedy: 1. Replace the APG Motor. 2. Replace the Main Board.
Description: APG Motor reversing error
The number of occurrences of reversing the APG Motor has reached a predetermined limit. • The polarity of APG Motor cable is opposite. • APG Motor failure
Description: APG Motor driving time-out error
Abnormally-long driving duration of the APG Motor was detected. • Irregular load • Firmware becomes out of control.
Description: APG Motor velocity deviation error
The APG Motor was driven at a speed abnormally faster than a predetermined one during acceleration or deceleration. • Irregular load • APG encoder failure • APG Motor failure • APG Motor driver failure
Remedy: 1. Replace the APG Motor. 2. Replace the Main Board.
Description: APG Motor lock error
• Connection failure of the APG Motor. • The APG Motor was driven at a speed abnormally slower than a predetermined one during operation. • Irregular load • APG encoder failure • APG Motor failuree
Description: ATC Motor overload error
Overcurrent to the ATC Motor was detected. • ATC Motor cable disconnection. • Irregular load • ATC Motor encoder failure • ATC Motor failure
Description: ATC Motor over speed error
The ATC Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • ATC Motor encoder failure • Sub-F Board failure • APG Motor driver failure
Remedy: 1. Replace the ATC Motor. 2. Replace the Sub-F Board. 3. Replace the Main Board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.