  • Code: 1615
  • Description: Reel Unit undetectable error during operation
    The connector of the Reel Unit was disconnected during the Reel Motor was operating.
  • Remedy: Connect the connector of the Reel Unit.
  • Code: 1616
  • Description: Roll Unit Board failure
    There is a problem with a specific bit on the board, which detects what device is connected to the board.
  • Remedy: Replace the Sub-F Board of the Roll Unit.
  • Code: 1617
  • Description: Reel Unit Board failure
    There is a problem with a specific bit on the board, which detects what device is connected to the board.
  • Remedy: Replace the Sub-F Board of the Reel Unit.
  • Code: 1618
  • Description: Roll/Reel Unit Board failure
    There is a problem with a specific bit on the board, which detects what device is connected to the board.
  • Remedy: Replace the Sub-F Board of the Roll Unit and Reel Unit .
  • Code: 1620
  • Description: Pressurizing initialization error
    The initialization process did not complete within a predetermined time period.
  • Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
  • Code: 1621
  • Description: Pressurizing/Suction switching error
    The pressurizing and suction processes did not complete within a predetermined time period.
  • Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
  • Code: 1622
  • Description: Operating time-out error
    The switching operation did not complete within a predetermined time period.
  • Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
  • Code: 1623
  • Description: Continuous revolution error
    The control terminal (Vre terminal) of the Pressure Motor driver has shorted out.
  • Remedy: 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.