Description: SDRAM error
Writing to the SDRAM was attempted, but nothing could be written to it.
Remedy: Replace the Main Board.
Code: 2003
Description: FLASH BOOT checksum error
• Installing the firmware has failed. • The Flash ROM is out of order.
Remedy: 1. Re-install the firmware. 1. Replace the Main Board.
Code: 200A
Description: F/W load error
Reading/decompressing the firmware has failed.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.
Code: 200D
Description: System interrupt watchdog time-out error
A system failure such as CPU failure, or defective cash has occurred.
Remedy: Replace the Main Board.
Code: 3000
Description: AC shut-off
The AC power has been shut off due to a power failure, unplugged, Power Supply Board failure, or Main Board failure or the like.
Remedy: 1. Replace the Power Supply Board. 2. Replace the Main Board.
Code: Dxxy
Description: Service call for FW debugging
This error is intended to be used in the product development stage. It is supposed to not occur with marketed product, but may occur due to an unexpected cause such as external noises.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.
Code: Fxxx
Description: CPU related service call
• There is something wrong with the firmware. • The Main Board is out of order.
Remedy: 1. Re-install the firmware. 2. Replace the Main Board.