Description: Pre Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.
Description: HTC common elements communication error
• Connection failure between the Main Board and Sub-E Board such as cable disconnection • There is something wrong with the elements on the Sub-E Board. • There is something wrong with the communication elements on the Main Board.
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the Main Board.
Description: Platen Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.