Code: 1943

Description: Platen Heater heat deviation error
The difference between the current temperature and target temperature exceeded a predetermined limit.
Remedy: 1. Replace the thermistor . 2. Replace the Platen Heater. 3. Replace the Main Board.

Code: 1944

Description: Platen Heater power supply abnormal error 1
Cable disconnection, breaking, blowout of a fuse, or heater failure.
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the Platen Heater.

Code: 1950

Description: After Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor (After Heater). 2. Replace the Main Board.

Code: 1952

Description: After Heater overheat error
A heater temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor (After Heater). 2. Replace the After Heater. 3. Replace the Main Board.

Code: 1953

Description: After Heater heat deviation error
The difference between the current temperature and target temperature exceeded a predetermined limit.
Remedy: 1. Replace the thermistor (After Heater). 2. Replace the After Heater. 3. Replace the Main Board.

Code: 1954

Description: After Heater power supply abnormal error 1
• Cable disconnection, breaking, blowout of a fuse, or heater failure. • AC cable (for the After Heater) disconnection
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the After Heater.

Code: 1A23

Description: RTC data invalid error
The various absolute time settings stored on the NVRAM are abnormal.
Remedy: If the error still occurs after resetting the date and time, perform the followings. 1. Replace the RTC backup battery. 2. Replace the Main Board.

Code: 1A26

Description: RTC Access T/O error
The RTC circuit on the Main Board malfunctions.
Remedy: 1. Turn the power off and remove the RTC backup battery. 2. After several seconds, re-attach the battery and turn the power back on. 3. Reset the date and time settings of the RTC using the Service Program.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie