Description: After Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor (After Heater). 2. Replace the Main Board.
Description: After Heater power supply abnormal error 1
• Cable disconnection, breaking, blowout of a fuse, or heater failure. • AC cable (for the After Heater) disconnection
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the After Heater.
Description: RTC data invalid error
The various absolute time settings stored on the NVRAM are abnormal.
Remedy: If the error still occurs after resetting the date and time, perform the followings. 1. Replace the RTC backup battery. 2. Replace the Main Board.
Description: RTC Access T/O error
The RTC circuit on the Main Board malfunctions.
Remedy: 1. Turn the power off and remove the RTC backup battery. 2. After several seconds, re-attach the battery and turn the power back on. 3. Reset the date and time settings of the RTC using the Service Program.